基于深度学习的自动三维头影测量标志点定位
本回顾性诊断研究训练并评估基于SpatialConfiguration-Net的深度学习流程,在CT扫描上自动定位三维头影测量标志点。训练/验证集160例、测试集38例,参考数据为33个标志点。测试集平均定位误差1.0±1.3毫米,2.0、2.5、3.0毫米成功检测率分别为90.4%、93.6%、95.4%;骨骼测量与人工可重复性在Bland-Altman 95%一致性界限内的比例为91.9%。
要点
- 测试集平均定位误差1.0±1.3毫米,3.0毫米成功检测率95.4%。
- 角度和线性测量平均误差分别为-0.3±1.3°和-0.1±0.7毫米。
- 骨骼变量91.9%在人工可重复性Bland-Altman 95%一致性界限内。
核心结论
- 该深度学习方法仍需改进,但在具有挑战性的测试集上提供了高精度的三维标志点定位,骨骼评估的可靠性与临床医生所获得的结果相当。
研究设计与样本
- 回顾性诊断研究,训练/验证集160例连续术前CT扫描,测试集38例。
- 参考数据为33个标志点,由1名操作者手动定位一次(n=178)或由3名操作者手动定位两次(n=20,仅测试集)。
主要发现
- 测试集平均定位误差1.0±1.3毫米。
- 2.0、2.5、3.0毫米成功检测率分别为90.4%、93.6%、95.4%。
- 角度和线性测量平均误差分别为-0.3±1.3°和-0.1±0.7毫米。
- 与手动可重复性比较,骨骼变量91.9%、牙槽变量71.8%的测量在Bland-Altman 95%一致性界限内。
- 测试集中1例CT扫描预测置信水平为「非常低」,已从整体分析中排除,但仍评估并讨论了相应结果。
关键数值与推荐
- 原文未报告。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The increasing use of 3-dimensional (3D) imaging by orthodontists and maxillofacial surgeons to assess complex dentofacial deformities and plan orthognathic surgeries implies a critical need for 3D cephalometric analysis. Although promising methods were suggested to localize 3D landmarks automatically, concerns about robustness and generalizability restrain their clinical use. Consequently, highly trained operators remain needed to perform manual landmarking. In this retrospective diagnostic study, we aimed to train and evaluate a deep learning (DL) pipeline based on SpatialConfiguration-Net for automatic localization of 3D cephalometric landmarks on computed tomography (CT) scans. A retrospective sample of consecutive presurgical CT scans was randomly distributed between a training/validation set (n = 160) and a test set (n = 38). The reference data consisted of 33 landmarks, manually localized once by 1 operator(n = 178) or twice by 3 operators (n = 20, test set only). After inference on the test set, 1 CT scan showed "very low" confidence level predictions; we excluded it from the overall analysis but still assessed and discussed the corresponding results. The model performance was evaluated by comparing the predictions with the reference data; the outcome set included localization accuracy, cephalometric measurements, and comparison to manual landmarking reproducibility. On the hold-out test set, the mean localization error was 1.0 ± 1.3 mm, while success detection rates for 2.0, 2.5, and 3.0 mm were 90.4%, 93.6%, and 95.4%, respectively. Mean errors were -0.3 ± 1.3° and -0.1 ± 0.7 mm for angular and linear measurements, respectively. When compared to manual reproducibility, the measurements were within the Bland-Altman 95% limits of agreement for 91.9% and 71.8% of skeletal and dentoalveolar variables, respectively. To conclude, while our DL method still requires improvement, it provided highly accurate 3D landmark localization on a challenging test set, with a reliability for skeletal evaluation on par with what clinicians obtain.
引用
- Dot G, Schouman T, Chang S, et al. Automatic 3-Dimensional Cephalometric Landmarking via Deep Learning. J Dent Res. 2022. PMID: 35982646. doi:10.1177/00220345221112333
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。