文献速递牙体牙髓病

改良荧光脂多糖牙本质感染模型及脂多糖取样技术比较XP-Endo精修锉与被动超声冲洗

A modified dentine infection model with fluorescent lipopolysaccharide and lipopolysaccharides sampling technique to compare XP-Endo finisher and passive ultrasonic irrigation.
PubMed 文献 · Int Endod J · 2022-08-11

本研究建立荧光脂多糖牙本质感染模型,并评估低温研磨根管内脂多糖取样技术,比较XP-Endo精修锉与被动超声冲洗去除根管内脂多糖的效果。共69颗下颌前磨牙,23颗用于共聚焦激光扫描显微镜验证模型,46颗随机分为XP-EF组(n=23)和PUI组(n=23)。结果显示两种方法均改善脂多糖消毒且无差异,XP-EF与PUI同样有效。

要点

  • 荧光脂多糖结合物在100%样本中经共聚焦显微镜检出,穿透牙本质深度约400微米。
  • XP-EF与PUI均进一步改善根管内脂多糖消毒(p<.05),两组间无差异(p>.05)。
  • 低温研磨取样在s4检出的残留脂多糖量约为纸尖取样s3的3倍。

核心结论

  • 本研究建立了使用荧光结合脂多糖的改良脂多糖牙本质感染模型,并验证了低温粉碎根管内脂多糖分析的取样技术。
  • XP-EF与PUI均进一步改善根管内脂多糖消毒,创新的XP-EF与PUI同样有效。

研究设计与样本

  • 共69颗下颌前磨牙行牙本质预处理并接种荧光脂多糖结合物(Alexa Fluor® 594)。
  • 23颗牙在共聚焦激光扫描显微镜下分析以验证改良脂多糖牙本质感染模型。
  • 46颗牙随机分为两组:XP-EF组(n=23)和PUI组(n=23)。
  • 所有牙使用XP-endo shaper(XPS;FKG Dentaire)和2.5% NaOCl进行器械预备。

主要发现

  • 荧光脂多糖结合物在100%的样本中经共聚焦激光扫描显微镜检出,穿透牙本质深度约400微米。
  • 使用XPS锉的化学机械预备显著降低脂多糖水平(p<.05)。
  • XPS和PUI均改善脂多糖消毒(p<.05),两者间无差异(p>.05)。
  • 低温研磨后所有样本均回收出脂多糖。
  • 低温取样技术在s4检出的残留脂多糖量约为纸尖取样技术在s3的3倍。

关键数值与推荐

  • 脂多糖定量采用鲎变形细胞溶解物试验。
  • 四个时间点(s1、s2、s3、s4)脂多糖差异采用Friedman检验,时间点两两比较采用Dunn检验,显著性水平设为5%(p<.05)。
  • 根管取样在器械预备前(s1)、后(s2)及XP-EF和PUI补充处理后(s3)用纸尖进行;s3后所有牙根低温研磨用于根管内脂多糖分析(s4)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: The lipopolysaccharides-dentine-infection (LPS-dentine-infection) models and sampling techniques frequently used to evaluate LPS disinfection have limitations. In this study, a LPS-dentine-infection model was devised using fluorescent conjugate LPS. Secondly, a sampling technique using cryogenic grinding for intraradicular LPS analysis was evaluated. Thirdly, the effectiveness of the XP-endo Finisher (XP-EF) was compared with passive ultrasonic irrigation (PUI) in removing LPS from root canal system. METHODOLOGY: Sixty-nine mandibular premolars were submitted to dentine pretreatment and inoculated with fluorescent LPS conjugate (Alexa Fluor® 594). Twenty-three teeth were analysed under confocal laser scanning microscopy (CLSM) to validate this modified LPS-dentine-infection model. Forty-six teeth were randomly divided into two experimental groups: XP-EF (n = 23) and PUI (n = 23). All teeth were instrumented with XP-endo shaper (XPS; FKG Dentaire) and 2.5% NaOCl. The root canals were sampled with paper points before (s1) and after (s2) instrumentation and after supplemental treatment (s3) with XP-EF and PUI. After s3, all roots were cryogenically ground for intraradicular LPS analysis (s4). Limulus amebocyte lysate assay was used for LPS quantification. The Friedman test was used for differences in LPS among four time-points (s1, s2, s3, and s4). Dunn's test was used for pairwise testing of time-points. The significance level was set at 5% (p < .05). RESULTS: Fluorescent LPS conjugate was detected in 100% of the samples under CLSM with a penetration depth of approximately 400 μm into dentine. Chemo-mechanical preparation using XPS files significantly reduced LPS levels (p < .05). Both the XPS and PUI improved the LPS disinfection (p < .05), with no difference between them (p > .05). LPS was recovered from all samples after cryogenic grinding. The residual amount of LPS detected using the cryogenically sampling technique at s4 was approximately three times greater than with the paper-point sampling technique at s3. CONCLUSION: This study established a modified LPS-dentine-infection model using fluorescent conjugate LPS, and validated a LPS sampling technique for using cryopulverization intraradicular LPS analysis. Moreover, both the XP-EF and PUI further improved LPS disinfection from the root canals, and the innovative XP-EF was as effective as PUI.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Alfirdous RA, Alquiria TA, Jacinto RC, et al. A modified dentine infection model with fluorescent lipopolysaccharide and lipopolysaccharides sampling technique to compare XP-Endo finisher and passive ultrasonic irrigation. Int Endod J. 2022. PMID: 35950779. doi:10.1111/iej.13804

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。