牙科综合治疗台水路中的次氯酸钠对牙髓治疗产生气溶胶中细菌的影响
本研究分两阶段在临床环境中用被动采样法评估不同牙髓操作产生的气溶胶播散,以及牙科综合治疗台水路(DUWL)中加入0.1%次氯酸钠(NaOCl)对气溶胶细菌载量的影响。结果显示除切开引流外所有操作均产生气溶胶,可播散至距患者头部3米处,各位置间无显著差异;DUWL中加入0.1% NaOCl显著降低所有治疗组气溶胶的细菌载量。
要点
- 除切开引流外,所有受试牙髓操作均产生气溶胶并播散至距患者头部3米处。
- 活髓保存全冠髓切断术产生的气溶胶数量最多。
- DUWL中加入0.1% NaOCl显著降低气溶胶细菌载量。
核心结论
- 所有受试牙髓操作均导致污染气溶胶的产生与播散,DUWL中加入0.1% NaOCl作为杀菌剂使细菌载量出现统计学显著降低。
研究设计与样本
- 研究分两阶段,采用脑心浸液琼脂平板被动采样法,在手术室预设位置放置平板。
- 阶段1共收集38份样本,包括基线及活髓保存全冠髓切断术(n=10)、非手术根管治疗(n=10)、手术根管治疗(n=10)和切开引流(n=8)操作中的样本。
- 阶段2共收集30份样本,所有操作(活髓保存全冠髓切断术n=10、非手术根管治疗n=10、手术根管治疗n=10)均在DUWL含0.1% NaOCl条件下进行。
主要发现
- 除切开引流外,所有牙髓操作在所有测试位置均产生气溶胶。
- 气溶胶播散至距患者头部3米处,各位置间无显著差异(P > .05)。
- 活髓保存全冠髓切断术产生的气溶胶数量最多,高于非手术根管治疗和手术根管治疗。
- 与未处理水路组相比,DUWL中加入0.1% NaOCl显著降低所有治疗组气溶胶中的细菌载量(P < .05)。
- 所有处理水路组间细菌载量无显著差异(P > .05)。
关键数值与推荐
- 细菌生长以采样后48小时的菌落形成单位表示。
- 阶段1数据采用单因素方差分析及Tukey多重比较事后检验。
- 阶段2数据采用双因素方差分析及Tukey多重比较事后检验。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Aerosol generation in a dental setting is a critical concern, and approaches that aim at decreasing bacterial load in aerosols are of high priority for dental professionals. The objectives of this study were to evaluate the relative effect of various endodontic procedures on the generation and dissemination of aerosols and the effect of 0.1% sodium hypochlorite (NaOCl) in dental unit waterlines (DUWLs) on the bacterial load in the generated aerosols in a clinical setting. METHODS: The study was completed in 2 phases. The classic passive sampling technique using brain-heart infusion agar plates was used. Agar plates were strategically placed throughout the operatory at predefined locations. In phase 1, to evaluate the effect of different endodontic procedures on the generation and dissemination of aerosols, we collected a total of 38 samples. After baseline collection, test samples were collected during vital pulp therapy (VPT) full pulpotomy (n = 10), nonsurgical root canal therapy (NSRCT, n = 10), surgical root canal therapy (SRCT, n = 10), and incision and drainage (n = 8) procedures. Bacterial growth was expressed as colony-forming units at 48 hours after sample collection. Data were analyzed using 1-way analysis of variance with the Tukey multiple comparison post hoc test. In phase 2, to evaluate the effect of 0.1% NaOCl in the DUWL on the bacterial load in the generated aerosols, a total of 30 samples were collected. All procedures including VPT (n = 10), NSRCT (n = 10), and SRCT (n = 10) were performed with 0.1% NaOCl in the DUWL. Bacterial growth was expressed as colony-forming units at 48 hours after sample collection. Data were analyzed using 2-way analysis of variance with the Tukey multiple comparison post hoc test. RESULTS: All endodontic procedures generated aerosols at all tested locations, except incision and drainage. Aerosols were disseminated as far as 3 m from the patient's head with no significant difference between various locations (P > .05). VPT procedures generated the maximum number of aerosols compared with NSRCT and SRCT. Adding 0.1% NaOCl to DUWLs significantly reduced the bacterial load in the generated aerosols in all treatment groups compared with groups treated with untreated waterlines (P < .05). No significant difference was noted in the bacterial load between all groups with treated waterlines (P > .05). CONCLUSIONS: All tested endodontic procedures led to the generation and dissemination of contaminated aerosols, and the addition of 0.1% NaOCl as a biocide to the DUWL led to a statistically significant reduction in the bacterial load.
引用
- Rayyan A, Ather A, Hargreaves KM, et al. Effect of Sodium Hypochlorite in Dental Unit Waterline on Aerosolized Bacteria Generated from Endodontic Procedures. J Endod. 2022. PMID: 36030970. doi:10.1016/j.joen.2022.07.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。