基台几何形态对早期种植体边缘骨丢失的影响:一项双盲随机6个月临床试验
一项双盲随机平行对照临床试验,比较圆柱形基台与凹面基台对早期边缘骨丢失(MBL)的影响。共77枚种植体(25例患者),圆柱形基台组38枚(49.4%),凹面基台组39枚(50.6%)。圆柱形基台组早期整体MBL为-0.6±0.7 mm,显著高于凹面基台组的-0.4±0.6 mm(p=.030)。结论:凹面基台在负载后6个月时的早期MBL显著少于传统圆柱形基台。
要点
- 圆柱形基台组早期整体MBL为-0.6±0.7 mm,显著高于凹面基台组的-0.4±0.6 mm(p=.030)。
- 圆柱形基台效应量ES=-1.3730(CI -2.5919至-0.1327;t=-2.4893;p=.0139),提示平均骨水平丢失。
- 凹面基台效应量ES=2.8231(CI 1.4379至4.2083;t=4.0957;p=.0002),提示平均骨水平增加。
核心结论
- 凹面基台在负载后6个月时的早期MBL显著少于传统圆柱形基台。
研究设计与样本
- 一项双盲、随机、平行两组临床试验,无对照组,比较圆柱形基台与凹面基台。
- 共80枚六角内连接种植体(直径4×10 mm)植入愈合的成熟骨内,最终样本为25例患者中的77枚种植体。
- 圆柱形基台组38枚(49.4%),凹面基台组39枚(50.6%)。
- 主要变量为种植体周围组织稳定性,以8周和6个月时的MBL衡量。
主要发现
- 圆柱形基台组早期整体MBL为-0.6±0.7 mm,显著高于凹面基台组的-0.4±0.6 mm(p=.030)。
- 圆柱形基台效应量ES=-1.3730(CI -2.5919至-0.1327;t=-2.4893;p=.0139),提示平均骨水平丢失。
- 凹面基台效应量ES=2.8231(CI 1.4379至4.2083;t=4.0957;p=.0002),提示平均骨水平增加。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The objective of this study was to analyze the impact of the abutment width on early marginal bone loss (MBL). MATERIAL AND METHODS: A balanced, randomized, double-blind clinical trial with two parallel experimental arms was conducted without a control group. The arms were "cylindrical" abutment and "concave" abutment. Eighty hexagonal internal connection implants, each with a diameter of 4 × 10 mm, were placed in healed mature bone. The main variable was the peri-implant tissue stability, which was measured as MBL at 8 weeks and 6 months. RESULTS: The final sample consisted of 77 implants that were placed in 25 patients. 38 (49.4%) were placed using the cylindrical abutment, and the other 39 (50.6%) were placed using the concave abutment. The early global MBL of -0.6 ± 0.7 mm in the cylindrical abutment group was significantly higher than it was in the concave abutment group, in which the early global MBL was -0.4 ± 0.6 mm (p = .030). The estimated effect size (ES) was negative for the cylindrical abutment (ES = -1.3730, CI -2.5919 to -0.1327; t-value = -2.4893; p = .0139), therefore implying a loss of mean bone level, and it was positive for the concave abutment (ES = 2.8231; CI: 1.4379 to 4.2083; t-value = 4.0957; p = .0002), therefore implying an increase in the average bone level. CONCLUSIONS: The concave abutments presented significantly less early MBL at 6 months post-loading than classical cylindrical abutments did.
引用
- Pérez-Sayans M, Castelo-Baz P, Penarrocha-Oltra D, et al. Impact of abutment geometry on early implant marginal bone loss. A double-blind, randomized, 6-month clinical trial. Clin Oral Implants Res. 2022. PMID: 35869615. doi:10.1111/clr.13985
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。