牙本质处理及壳聚糖-羟基磷灰石纳米复合物改性封闭剂对根管牙本质抗菌与力学特性的影响
本研究评估生物可矿化壳聚糖-羟基磷灰石前体(CS-HA)纳米复合物单独或联合硅酸三钙封闭剂(TCS/CS-HA)处理牙本质后的力学性能与抗生物膜效果。结果显示,CS-HA处理提高根管牙本质抗折性并降低残余细菌负荷,TCS/CS-HA增强TCS的纳米力学与物理性能。
要点
- CS-HA处理牙本质可提高抗折性并减少粪肠球菌负荷。
- TCS/CS-HA提高纳米硬度和弹性模量,且不影响溶解度。
- CS-HA处理后的根管充填TCS或TCS/CS-HA可进一步减少细菌。
核心结论
- CS-HA改性牙本质可提高根管牙本质抗折性并降低残余细菌负荷。
- TCS/CS-HA增强了TCS的纳米力学和物理性能。
研究设计与样本
- 体外研究,评估CS-HA纳米复合物单独或联合TCS对根管牙本质力学性能与抗生物膜效果的影响。
- 抗折性实验使用下颌前磨牙,随机分为7组,每组n=8。
- 抗菌实验使用粪肠球菌感染的根管,采用相似的根管预备与分组流程。
主要发现
- TCS/CS-HA浸泡4周后溶解性无显著变化(P > .05)。
- TCS/CS-HA的纳米硬度为210 ± 11.3 MPa、弹性模量为7.9 ± 0.9 GPa,TCS分别为44.5 ± 7.8 MPa、2.1 ± 0.3 GPa(P < .05)。
- NaOCl-EDTA冲洗后抗折性为444.34 N,CS-HA单独处理为928.28 N(P < .05),CS-HA处理联合CS-HA/TCS充填为1134.06 N(P < .05)。
- CS-HA处理使细菌从初始负荷6.54 ± 0.07 log减少2.04 log至4.50 ± 0.43(P < .05)。
- CS-HA处理后根管充填TCS或TCS/CS-HA,细菌降至0.00至0.98 ± 0.57(P > .05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study aimed to characterize the effectiveness of dentin conditioning with bio-mineralizable chitosan-hydroxyapatite precursor (CS-HA) nanocomplexes alone or associated with tricalcium silicate sealer (TCS/CS-HA) on the mechanical property and antibiofilm efficacy in root dentin. METHODS: Flow tests were performed following ISO6876:2012 specifications. Solubility was measured. Micromorphology was assessed using scanning electron microscopy (SEM). Nanohardness/elastic modulus were also determined. Fracture resistance was determined on lower premolars that were prepared, and randomly distributed among 7 groups (n = 8/group), including the control, CS-HA dentin-conditioning, and root canal-filled groups. Similar canal preparation/distribution procedure was followed to test the antibacterial effect on Enterococcus faecalis-infected roots. Descriptive statistics was used to report SEM findings. Flowability results were analyzed using paired t test. Multiple comparisons from solubility, fracture, and antibacterial assays were assessed by one-way analysis of variance-Tukey's tests. RESULTS: TCS/CS-HA showed optimal flow and no effect on solubility after immersion for 4 weeks (P > .05). TCS/CS-HA significantly increased nanohardness and elastic modulus (210 ± 11.3 MPa, 7.9 ± 0.9 GPa) compared with TCS (44.5 ± 7.8 MPa, 2.1 ± 0.3 GPa, P < .05). SEM revealed needle-shaped mineralized structures resulting in fewer voids and a well-adapted sealer-dentin interface in the TCS/CS-HA groups. NaOCl-EDTA irrigation resulted in reduced fracture resistance (444.34 N), whereas CS-HA dentin conditioning alone (928.28 N, P < .05) and CS-HA dentin-conditioning plus CS-HA/TCS resulted in higher fracture resistance (1134.06 N, P < .05). CS-HA dentin conditioning also reduced bacteria by 2.04 log (4.50 ± 0.43) from the initial bacterial load (6.54 ± 0.07, P < .05). There was further bacterial reduction when CS-HA-conditioned root canals were filled with TCS or TCS/CS-HA (0.00 to 0.98 ± 0.57, P > .05). CONCLUSION: Dentin modification with CS-HA increased the fracture resistance of root dentin, and decreased the residual bacterial burden. TCS/CS-HA potentiated the nanomechanical and physical properties of TCS.
引用
- Del Carpio-Perochena A, Nicholson E, Singh CV, et al. Impact of Dentin Conditioning and Sealer Modification With Chitosan-Hydroxyapatite Nanocomplexes on the Antibacterial and Mechanical Characteristics of Root Dentin. J Endod. 2022. PMID: 35809810. doi:10.1016/j.joen.2022.06.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。