文献速递口腔修复与种植

种植体扫描体斜面位置、种植体角度和位置对口内扫描精度的影响:一项体外研究

Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study.
PubMed 文献 · J Dent · 2022-04-06

该体外研究评估扫描体几何斜面位置及种植体角度和位置对全牙弓种植体数字化扫描精度的影响。研究制作平行(P组)和倾斜达30°(NP组)的种植体模型,按斜面位置分面部、近中、远中、舌侧和随机五组,用实验室扫描仪作参考、口内扫描仪(TRIOS 3)获取实验扫描,计算种植体位置偏差。结果显示扫描体斜面位置、种植体角度和种植体间距均为线性偏差和角度偏差的显著预测因素。

要点

  • 扫描体斜面位置、种植体角度和种植体间距均为线性偏差和角度偏差的显著预测因素(P < .001)。
  • 舌侧斜面组(L组)的线性偏差显著低于其他斜面组。
  • 平行种植体组的精度优于倾斜种植体组;扫描终止处的种植体形变显著高于对侧种植体。

核心结论

  • 扫描体几何斜面位置及种植体角度和位置影响所测试口内扫描仪的精度。
  • 舌侧方向的精度值显著优于其他位置。
  • 平行种植体模拟位置获得比倾斜位置更好的精度。
  • 位于口内数字化扫描终止处的种植体,其形变显著高于对侧种植体。

研究设计与样本

  • 体外研究,制作两个含4个种植体模拟体的终模型,分为平行组(P组)和倾斜达30°组(NP组)。
  • 按扫描体几何斜面位置分为面部、近中、远中、舌侧和随机五个亚组(F、M、D、L、R亚组)。
  • 使用实验室扫描仪(7Series Desktop Scanner)作为参考,口内扫描仪(TRIOS 3)获取实验扫描。
  • 计算参考扫描与实验扫描之间的种植体位置偏差,采用三因素方差分析和Tukey检验(α = .05)。

主要发现

  • 扫描体几何斜面位置(P < .001)和种植体间距(P < .001)是线性偏差的显著预测因素。
  • L亚组的线性偏差显著低于其他亚组。
  • 种植体角度(P < .001)、扫描体几何斜面位置(P < .001)和种植体间距(P < .001)均为角度偏差的显著预测因素。
  • 平行种植体模拟位置获得比倾斜位置更好的精度。
  • 位于口内数字化扫描终止处的种植体形变显著高于对侧种植体。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the influence of the scan body geometry bevel location and implant angulation and position of complete-arch implant digital scans. MATERIAL AND METHODS: Two definitive casts with 4 implant analogs placed parallel (P group) or angulated up to 30° (NP group) were fabricated. Five subgroups were created based on the scan body geometry bevel position: facial, mesial, distal, lingual, or random (F, M, D, L, and R subgroup). Casts were digitized using a laboratory scanner (reference) (7Series Desktop Scanner) and an intraoral scanner (TRIOS 3). The implant position discrepancies between the reference and experimental scans were calculated. Data was analyzed using 3-way ANOVA and Tukey tests (α = .05). RESULTS: The scan body geometry bevel position (P < .001) and the inter-implant distance (P < .001) were shown as significant predictors of the linear discrepancies obtained. The L subgroup had a significantly lower discrepancy compared with the other subgroups. Implant angulation (P < .001), the scan body geometry bevel position (P < .001), and the inter-implant distance (P < .001) were all significant predictors on the angular discrepancies obtained. CONCLUSIONS: The scan body geometry bevel location and implant angulation and position influenced the accuracy of the IOS tested. The lingual orientation obtained significantly better accuracy values compared with the other positions. The parallel implant analog position obtained better accuracy than the angulated positions. Lastly, the implant positioned in the dental arch where the intraoral digital scan was finished obtained significantly higher distortion than the contralateral implant.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Gómez-Polo M, Álvarez F, Ortega R, et al. Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study. J Dent. 2022. PMID: 35395345. doi:10.1016/j.jdent.2022.104122

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。