微计算机断层扫描评估椭圆形根管中牙胶-封闭剂界面含间隙区域
本研究用微计算机断层扫描评估两种根管封闭剂(EndoSequence BC Sealer与AH Plus)在椭圆形根管单尖法充填后与牙胶锥界面的间隙分布。共16颗牙配对分组,每组8颗,结果显示两组均有间隙且非均匀分布,AH Plus组含间隙切片比例低于EndoSequence BC Sealer组,差异有统计学意义。
要点
- 椭圆形根管单尖法充填后牙胶-封闭剂界面均存在间隙,无完全无间隙标本。
- AH Plus组含间隙切片136/453(30.02%)低于EndoSequence BC Sealer组171/453(37.75%)。
- 两组间隙切片频率差异有统计学意义(p = .000)。
核心结论
- 尽管没有标本在整个牙胶-封闭剂界面完全无间隙,但AH Plus充填的椭圆形根管比EndoSequence BC Sealer充填的根管间隙更少。
研究设计与样本
- 选取16颗椭圆形根管牙齿,微计算机断层扫描后按根管体积、纵横比和构型配对。
- 根管依次用WaveOne Gold Primary和Large器械预备,再用WaveOne Large牙胶尖配合EndoSequence BC Sealer或AH Plus封闭剂以单尖法充填,每组8颗。
- 标本在37°C磷酸盐缓冲盐水中储存7天后重新扫描,分割图像区分充填材料与牙本质。
- 共评估453个横截面切片,按牙胶-封闭剂界面有无间隙分类,用Mann-Whitney U检验比较组间差异,α=5%。
主要发现
- 间隙在二维轴位横截面图像中非均匀分布,无标本整个牙胶-封闭剂界面完全无间隙。
- EndoSequence BC Sealer组有171个切片(37.75%)牙胶-封闭剂界面存在间隙,AH Plus组有136个切片(30.02%)存在间隙,差异有统计学意义(p = .000)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To assess the interfacial adaptation (gap-containing areas) of two root canal sealers (EndoSequence BC Sealer and AH Plus) to a conventional gutta-percha (GP) cone (GP-sealer interface) in oval-shaped canals filled using the single cone technique. METHODOLOGY: Sixteen teeth with oval-shaped canals were selected, scanned in a micro-computed tomographic device, and pair-matched according to the volume, aspect ratio and configuration of root canals. Root canals were then sequentially prepared with WaveOne Gold Primary and Large instruments, followed by filling with WaveOne Large GP points associated with either the premixed calcium-silicate EndoSequence BC Sealer or the epoxy resin-based AH Plus sealer (n = 8 per group) using the single cone technique. After 7 days stored in phosphate-buffered saline solution at 37°C, the specimens were rescanned and the reconstructed images segmented in order to differentiate the filling materials (sealer and GP cone) to the dentine. A total of 453 cross-sectional slices were assessed and categorized according to the presence or absence of gaps at the GP-sealer interface. Mann-Whitney U-test verified the differences between groups and were considered significant at alpha = 5%. RESULTS: Gaps were non-homogenously distributed in two-dimensional axial cross-section images and none of the specimens showed completely gap-free areas along the entire GP-sealer interface. Root canals filled with EndoSequence BC Sealer and AH Plus displayed 171 (37.75%) and 136 (30.02%) slices with gaps in the GP-sealer interface and these frequencies were statistically significant (p = .000). CONCLUSIONS: Although none of the specimens had a gap-free area along the entire GP-sealer interface, oval canals filled with AH Plus showed less gaps than the ones filled with EndoSequence BC Sealer.
引用
- De-Deus G, Santos GO, Monteiro IZ, et al. Micro-CT assessment of gap-containing areas along the gutta-percha-sealer interface in oval-shaped canals. Int Endod J. 2022. PMID: 35383977. doi:10.1111/iej.13744
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。