文献速递牙体牙髓病

非器械技术去除根管内多菌种生物膜的体外疗效

In vitro efficacy of a non-instrumentation technique to remove intracanal multispecies biofilm.
PubMed 文献 · Int Endod J · 2022-03-08

本研究以人牙菌斑来源的多菌种生物膜感染22颗下颌切牙,比较常规器械联合6%次氯酸钠冲洗与非器械GentleWave系统清洁的效果。两种方法清洁后样本读数均显著减少,常规清洁后读数显著少于非器械清洁;非器械清洁后链球菌属、韦荣球菌属和弯曲杆菌属相对丰度显著更高。

要点

  • 两种清洁方案均显著减少根管内细菌读数(p < .0001)。
  • 常规清洁后样本读数显著少于非器械清洁(p = .002)。
  • 非器械清洁后链球菌属、韦荣球菌属和弯曲杆菌属相对丰度显著更高。

核心结论

  • 两种方案清洁后群落组成均发生显著变化,但常规清洁技术的影响更大。

研究设计与样本

  • 体外研究,使用22颗下颌切牙建立人牙菌斑来源的多菌种生物膜感染模型。

主要发现

  • 生物样本总读数范围为126至45 286。
  • 两种方法清洁后样本读数均显著减少(p < .0001)。
  • 常规清洁后样本读数显著少于非器械清洁(p = .002)。
  • 非器械清洁后链球菌属、韦荣球菌属和弯曲杆菌属相对丰度显著更高(Kruskal-Wallis p = .009、.033和.001)。
  • Shannon alpha多样性无显著差异,但清洁后样本Chao1指数显著更低。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: The aim of this study was to assess the efficacy of a non-instrumentation technique to disinfect root canals infected by a human dental plaque-derived multispecies biofilm. METHODOLOGY: Twenty-two mandibular incisors were accessed, autoclaved and inoculated with dental plaque. The Center for Disease Control biofilm reactor was used to promote contamination of the root canal space. In the conventional technique (control), the specimens were instrumented until size 35/04 and irrigated with 6% NaOCl. In the non-instrumentation technique, a glide path was established using K-files size 10-20 and specimens were immediately cleaned with the GentleWave System. Samples were obtained for culture and 16S rRNA gene sequencing. Differences in abundances of genera were evaluated using Kruskal-Wallis test, and differences in alpha diversity were compared using anova. Alpha and beta diversity indices were calculated using mothur. The Shannon and Chao1 indices were used to measure alpha diversity. The Bray-Curtis dissimilarity was used to measure beta diversity. Differences in community composition were evaluated using analysis of similarity with Bonferroni correction for multiple comparisons. RESULTS: The total numbers of reads in biological samples ranged from 126 to 45 286. Significantly fewer reads were obtained from samples following cleaning by either method (p < .0001), and significantly fewer reads were obtained in post-cleaning samples following conventional versus non-instrumentation cleaning regiment (p = .002). Communities in pre-treatment samples were similar in both groups; however, significantly greater relative abundances of Streptococcus, Veillonella and Campylobacter were observed following cleaning using non-instrumentation technique (Kruskal-Wallis p = .009, .033, and .001, respectively). Whilst no significant differences were observed in Shannon alpha diversity, the Chao1 index was significantly lower in post-cleaning samples. CONCLUSIONS: Significant shifts in composition were observed following cleaning by using both regimens, but the impact of this change was greater following a conventional cleaning technique.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Ordinola-Zapata R, Mansour D, Saavedra F, et al. In vitro efficacy of a non-instrumentation technique to remove intracanal multispecies biofilm. Int Endod J. 2022. PMID: 35152445. doi:10.1111/iej.13706

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。