锥形束CT生成牙齿复制品应用于自体移植的精度评估
本研究从患者CBCT数据分割生成16颗牙齿复制品,用Polyjet、激光立体光刻(SLA)和数字光处理(DLP)三种打印技术制作,并与实际牙齿比较线性和几何精度,同时评估热灭菌后的尺寸变化。结果显示复制品与实际牙齿存在显著差异,Polyjet打印机精度最高(p<0.0001),灭菌后变化在临床上不显著。
要点
- CBCT生成的3D打印牙齿复制品与实际牙齿在长度和几何尺寸上存在显著差异。
- Polyjet打印技术制作的模型精度高于SLA和DLP打印机(p<0.0001)。
- 热灭菌后复制品尺寸变化在临床上不显著(平均长度差0.10 mm,RMS偏差0.02 mm)。
核心结论
- 牙齿复制品与实际牙齿的线性和几何测量存在显著差异。
- Polyjet技术打印机比SLA或DLP打印机能产生更准确的模型。
- 打印牙齿模型在热灭菌后表现出临床上不显著的变化。
研究设计与样本
- 从招募患者中选取16颗牙齿样本。
- 从患者CBCT数据分割生成文件,分别用Polyjet、激光立体光刻(SLA)和数字光处理(DLP)三种打印机制作牙齿复制品。
- 复制品与实际牙齿经光学扫描仪扫描,复制品灭菌后再扫描,并进行配对叠加分析。
主要发现
- 复制品与实际牙齿的平均长度差异为0.36 mm,平均几何(均方根[RMS])差异为0.56 mm。
- 定性分析显示复制品通常尺寸偏大。
- 重复测量方差分析显示Polyjet打印机精度最高(p<0.0001)。
- 灭菌后总体平均长度差异为0.10 mm,RMS偏差为0.02 mm。
临床怎么用
- 基于患者CBCT数据的3D打印牙齿复制品可用于自体移植以提高手术可预测性。
- 为使这一新型数字化方法发挥潜力,必须解决各种打印技术制作复制品精度的问题。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The primary aim of this study was to assess the linear and geometric accuracy of 3-dimensional (3D) printed tooth replicas when compared to the actual tooth. The secondary aims were to compare the accuracy of three different 3D printers and to evaluate dimensional changes of tooth replicas after sterilization. METHODS: A sample of 16 teeth were selected from recruited patients. Segmentation was carried out to generate files from the patient's cone beam computed tomography (CBCT) data, Tooth replicas were then printed using three printers making use of Polyjet, laser stereolithography (SLA) and digital light processing (DLP) technology respectively. These replicas, along with the actual tooth, were scanned by an optical scanner. Replicas were sent for sterilization and scanned again. Paired superimposition of the scans was performed. RESULTS: A mean length difference of 0.36 mm and mean geometric (root mean square [RMS]) difference of 0.56 mm was found. Qualitative analysis showed that the replicas were generally larger in size. Repeated ANOVA tests showed that the Polyjet printer had the highest accuracy (p<0.0001). After sterilization, there was an overall mean length difference of 0.10 mm and RMS deviation of 0.02 mm. CONCLUSION: This study found that there was a significant difference in linear and geometric measurements of the tooth replicas when compared to the actual tooth. This study also provides evidence that the printer which made use of Polyjet technology was able to produce more accurate models than SLA or DLP printers. Printed tooth models demonstrated clinically insignificant changes after heat sterilization. CLINICAL SIGNIFICANCE: 3D printed tooth replicas derived from the patient's CBCT data may be used in autotransplantation to increase predictability of the procedure. In order for this novel digital approach to realize its potential, it is critical to address questions as to how accurate the various printing technologies are in fabricating replicas.
引用
- Lee CKJ, Foong KWC, Sim YF, et al. Evaluation of the accuracy of cone beam computed tomography (CBCT) generated tooth replicas with application in autotransplantation. J Dent. 2021. PMID: 34856326. doi:10.1016/j.jdent.2021.103908