带正电荷聚偏氟乙烯膜:牙髓治疗中吸潮纸尖的潜在替代品
本研究比较了带正电荷与不带电荷聚偏氟乙烯膜(PVDFM)及三种市售吸潮纸尖(PP)的吸水能力,并检测其结合与清除内毒素的能力。结果显示PVDFM吸水能力高于PP(P < .05),带正电荷PVDFM清除内毒素多于不带电荷PVDFM和PP(P < .05)。作者认为孔径0.22 μm的带正电荷PVDFM可能替代牙髓治疗中使用的PP。
要点
- 带正电荷与不带电荷PVDFM的吸水率均高于吸潮纸尖(P < .05),两者间无差异(P > .05)。
- 带正电荷PVDFM清除内毒素多于不带电荷PVDFM和PP(P < .05)。
- 不带电荷PVDFM结合并清除内毒素多于任一种PP(P < .05)。
核心结论
- PVDFM原型尖的吸水能力高于吸潮纸尖,且带正电荷PVDFM结合与清除内毒素的效果优于不带电荷PVDFM和吸潮纸尖。
- 本研究提示孔径0.22 μm的带正电荷PVDFM可能替代牙髓治疗中使用的吸潮纸尖。
研究设计与样本
- 体外研究,将三种市售吸潮纸尖与PVDFM原型尖(Millipore Sigma,Burlington,MA)进行比较。
- 使用数字天平以±0.0001精度记录每种吸潮纸尖和PVDFM的初始干重,浸入去离子水后称湿重,按公式计算吸水率:百分比增加 =([湿重-干重]/干重)× 100。
- 内毒素清除实验:先将吸潮纸尖和PVDFM浸入含10 EU/mL大肠杆菌O55:B5(Lonza,Walkersville,MD)的24孔板,定量孔中剩余内毒素,再提取并定量吸潮纸尖和PVDFM上的内毒素,使用Kinetic-QCL试验(Lonza)定量内毒素。
主要发现
- 带正电荷与不带电荷PVDFM的吸水率均高于吸潮纸尖(P < .05),两者之间无差异(P > .05)。
- 带正电荷PVDFM清除的内毒素多于不带电荷PVDFM和吸潮纸尖(P < .05)。
- 不带电荷PVDFM结合并清除的内毒素多于任何一种吸潮纸尖(P < .05)。
临床怎么用
- 作者认为,孔径0.22 μm的带正电荷PVDFM可能替代牙髓治疗中使用的吸潮纸尖。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study compared the absorbency capacity of paper points (PPs) with positively charged and noncharged polyvinylidene fluoride membranes (PVDFMs) and investigated the ability of PPs and PVDFMs to bind and remove endotoxin. METHODS: Three commercially available PPs were compared with PVDFM (Millipore Sigma, Burlington, MA) prototype points. We recorded the initial dry weight for each PP and PVDFM using a digital balance to ±0.0001 precision for absorbency. PPs and PVDFMs were then immersed in deionized water and weighed to obtain the wet weight. The absorbency was calculated with the following formula: percent increase = ([wet weight - dry weight]/dry weight) × 100. For endotoxin removal, we first quantified endotoxin remaining in wells after immersing PPs and PVDFMs in a 24-well plate containing 10 endotoxin units/mL Escherichia coli O55:B5 (Lonza, Walkersville, MD). We then extracted and quantified endotoxin from PPs and PVDFMs. Endotoxin was quantified using the Kinetic-QCL test (Lonza). RESULTS: The absorbencies for the positively charged and noncharged PVDFMs were higher than the PPs (P < .05), with no difference between them (P > .05). The positively charged PVDFMs removed more endotoxin than the noncharged PVDFMs and the PPs (P < .05). Moreover, the noncharged PVDFMs bound and removed more endotoxin than any PPs (P < .05). CONCLUSIONS: PVDFM prototype points are more absorbent than PPs. Moreover, the positively charged PVDFM points are more effective in binding and removing endotoxin than noncharged PVDFMs and PPs. This study suggests that positively charged PVDFMs with a 0.22-μm pore size could potentially replace PPs used in endodontics.
引用
- Yeung WY, Tordik PA, Martinho FC, et al. Positively Charged Polyvinylidene Fluoride Membrane: A Potential Alternative for Absorbent Paper Points in Endodontics. J Endod. 2021. PMID: 34813795. doi:10.1016/j.joen.2021.11.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。