左心室辅助装置流出道吻合至降主动脉的长期结局
单中心回顾性研究比较连续流离心泵左心室辅助装置(LVAD)经胸廓切开、流出道吻合至降主动脉与标准升主动脉吻合的长期生存与再入院情况,共纳入330例生存分析患者,结果显示两组住院、6个月、1年、3年及5年死亡率无显著差异。
要点
- 降主动脉吻合组与升主动脉吻合组长期生存无显著差异。
- 校正患者特征后再入院相关指标两组无显著差异。
- 经胸廓切开降主动脉吻合可作为避免前纵隔平面的替代植入方式。
核心结论
- 经胸廓切开、流出道吻合至降主动脉的LVAD植入与标准植入在长期生存和再入院方面无差异。
研究设计与样本
- 单中心回顾性分析,成人连续流离心泵LVAD植入患者,按流出道吻合部位分为升主动脉组(Asc-Ao)与降主动脉组(Desc-Ao)。
- 生存分析纳入330例(Asc-Ao 272例,Desc-Ao 58例);再入院分析纳入出院后生存≥30天的277例(Asc-Ao 231例,Desc-Ao 46例)。
- 采用多变量分析和倾向性评分匹配。
主要发现
- 两组住院、6个月、1年、3年及5年死亡率无显著差异。
- 再入院分析共分析654患者年随访期间的1028次再入院。
- 校正患者特征后,无再入院生存、30天再入院、每年入院次数及每年住院时长两组均无显著差异。
临床怎么用
- 对于需避免前纵隔平面的LVAD候选患者,经胸廓切开降主动脉流出道吻合可作为替代植入策略。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Left ventricular assist device (LVAD) implantation via thoracotomy with outflow cannula anastomosis to the descending aorta is an alternative implantation technique that uses a single incision and avoids anterior mediastinal planes. We evaluated long-term survival and hospital readmissions after LVAD implantation via thoracotomy with outflow cannula anastomosis to the descending aorta. METHODS: Adult patients implanted with a continuous flow centrifugal LVAD at an academic center were retrospectively analyzed. Patients were assigned to 1 of 2 cohorts based on the anastomosis site of the LVAD outflow cannula: ascending aorta cohort (Asc-Ao) and descending aorta cohort (Desc-Ao). Primary and secondary outcomes were survival and hospital readmissions during device support. Readmission analysis included patients with ≥30-day survival after discharge. Multivariable analysis and propensity score matching were performed. RESULTS: Survival analysis included 330 patients (Asc-Ao: 272, Desc-Ao: 58). Readmission analysis included 277 patients (Asc-Ao: 231, Desc-Ao: 46) and a total of 1028 readmissions during 654 patient-years of follow-up were analyzed. There was no significant difference in in-hospital, 6-month, 1-year, 3-year, and 5-year mortality between the two cohorts. Readmission-free survival, 30-day readmission, number of admissions per year and hospital length of stay per year were not significantly different between the 2 cohorts after adjustment for patient characteristics. CONCLUSIONS: This study found no difference in long-term survival or hospital readmissions between LVAD implantation via thoracotomy with outflow cannula anastomosis to the descending aorta and standard implantation.
引用
- Dorken Gallastegi A, Hoşcoşkun EB, Kahraman Ü, et al. Long-Term Outcomes in Ventricular Assist Device Outflow Cannula Anastomosis to the Descending Aorta. Ann Thorac Surg. 2021. PMID: 34627768. doi:10.1016/j.athoracsur.2021.08.071
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。