文献速递瓣膜外科

三维打印左心模拟器中改良包涵技术行Ross手术的离体生物力学分析

Ex vivo biomechanical analysis of the Ross procedure using the modified inclusion technique in a 3-dimensionally printed left heart simulator.
PubMed 文献 · J Thorac Cardiovasc Surg · 2021-09-16

该离体研究在三维打印左心模拟器中评估包涵技术行Ross手术的肺动脉瓣生物力学,比较有无抗连合折叠(ACP)的效果。猪自体移植瓣叶反流在包涵技术后显著低于对照组(P<.01),ACP与猪和人自体移植瓣叶更低的快速开放速度等更有利生物力学相关。需在体验证以转化临床。

要点

  • 包涵技术行Ross手术在离体模拟器中显示优异血流动力学结果
  • ACP可降低猪和人肺动脉自体移植瓣叶的快速开放速度等生物力学指标
  • 研究为离体实验,需在体验证后方可临床转化

核心结论

  • 包涵技术行Ross手术在离体模拟器中展示优异血流动力学参数结果。
  • ACP技术与更有利的瓣叶生物力学相关,但需在体验证以直接转化临床实践。

研究设计与样本

  • 离体实验研究,使用三维打印左心模拟器。
  • 纳入7个猪和5个人肺动脉自体移植瓣,另5个猪未加强自体移植瓣为对照。
  • 同一标本在有和无ACP条件下测试,收集血流动力学、超声和高速度摄影数据。

主要发现

  • 猪自体移植瓣反流在包涵技术后显著低于对照组(P<.01)。
  • 猪自体移植瓣ACP与非ACP相比:快速开放速度3.9±2.4 cm/sec vs 5.9±2.4 cm/sec,P=.03;快速关闭速度1.9±1.6 cm/sec vs 3.1±2.0 cm/sec,P=.01;相对快速开放力4.6±3.0 vs 7.7±5.2,P=.03;相对快速关闭力2.5±3.4 vs 5.9±2.3,P=.17。
  • 人自体移植瓣ACP与非ACP相比:快速开放速度3.5±0.9 cm/sec vs 4.4±1.0 cm/sec,P=.01;快速关闭速度1.8±0.7 cm/sec vs 2.2±0.3 cm/sec,P=.13;相对快速开放力3.0±0.6 vs 4.0±2.1,P=.30;相对快速关闭力1.4±1.3 vs 2.3±0.6,P=.25。

临床怎么用

  • 包涵技术行Ross手术可能减少猪自体移植瓣反流,ACP可能改善瓣叶生物力学,但需在体验证后方可临床常规应用。

局限性

  • 研究为离体实验,需在体验证以直接转化临床实践。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The inclusion technique was developed to reinforce the pulmonary autograft to prevent dilation after the Ross procedure. Anticommissural plication (ACP), a modification technique, can reduce graft size and create neosinuses. The objective was to evaluate pulmonary valve biomechanics using the inclusion technique in the Ross procedure with and without ACP. METHODS: Seven porcine and 5 human pulmonary autografts were harvested from hearts obtained from a meat abattoir and from heart transplant recipients and donors, respectively. Five additional porcine autografts without reinforcement were used as controls. The Ross procedure was performed using the inclusion technique with a straight polyethylene terephthalate graft. The same specimens were tested both with and without ACP. Hemodynamic parameter data, echocardiography, and high-speed videography were collected via the ex vivo heart simulator. RESULTS: Porcine autograft regurgitation was significantly lower after the use of inclusion technique compared with controls (P < .01). ACP compared with non-ACP in both porcine and human pulmonary autografts was associated with lower leaflet rapid opening velocity (3.9 ± 2.4 cm/sec vs 5.9 ± 2.4 cm/sec; P = .03; 3.5 ± 0.9 cm/sec vs 4.4 ± 1.0 cm/sec; P = .01), rapid closing velocity (1.9 ± 1.6 cm/sec vs 3.1 ± 2.0 cm/sec; P = .01; 1.8 ± 0.7 cm/sec vs 2.2 ± 0.3 cm/sec; P = .13), relative rapid opening force (4.6 ± 3.0 vs 7.7 ± 5.2; P = .03; 3.0 ± 0.6 vs 4.0 ± 2.1; P = .30), and relative rapid closing force (2.5 ± 3.4 vs 5.9 ± 2.3; P = .17; 1.4 ± 1.3 vs 2.3 ± 0.6; P = .25). CONCLUSIONS: The Ross procedure using the inclusion technique demonstrated excellent hemodynamic parameter results. The ACP technique was associated with more favorable leaflet biomechanics. In vivo validation should be performed to allow direct translation to clinical practice.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Zhu Y, Marin-Cuartas M, Park MH, et al. Ex vivo biomechanical analysis of the Ross procedure using the modified inclusion technique in a 3-dimensionally printed left heart simulator. J Thorac Cardiovasc Surg. 2021. PMID: 34625236. doi:10.1016/j.jtcvs.2021.06.070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。