三维CT评估预测快速部署主动脉瓣置换术后传导阻滞与瓣周漏

3-Dimensional computed tomographic assessment predicts conduction block and paravalvular leakage after rapid-deployment aortic valve replacement.
PubMed 文献 · Eur J Cardiothorac Surg · 2022-01-01

本研究回顾性分析187例接受快速部署主动脉瓣置换术(RDAVR)患者的术前CT,发现完全性房室传导阻滞(CAVB)与假体相对左室流出道(LVOT)过大相关,而瓣周漏(PVL)与假体相对主动脉瓣环过小相关。CT参数可高可靠预测CAVB或PVL,支持基于CT的假体尺寸选择。

要点

  • CAVB与RDAVR假体相对LVOT过大相关,ΔLVOTarea<1.3时CAVB预测概率<3%。
  • PVL与RDAVR假体相对主动脉瓣环过小相关,index Annlong有高预测价值。
  • 术前CT评估主动脉瓣环与LVOT参数有助于优化RDAVR假体尺寸选择。

核心结论

  • 主动脉瓣环和LVOT的CT参数可高度可靠地预测RDAVR术后CAVB或PVL。
  • 数据支持基于CT的RDAVR假体尺寸选择。

研究设计与样本

  • 回顾性分析2016年2月至2019年12月接受RDAVR(INTUITY ELITE)患者的术前CT图像。
  • 共纳入187例符合条件的患者。

主要发现

  • CAVB需永久起搏器植入发生于12例(6.4%),PVL(≥轻度)发生于11例(5.9%)。
  • CAVB与假体过大相关:ΔLVOTarea的比值比为2.05(95%CI 1.28-3.30),AUC为0.78(P=0.005)。
  • ΔLVOTarea<1.3时CAVB预测概率<3%。
  • PVL与假体过小相关:index Annlong的比值比为0.64(95%CI 0.51-0.79),AUC为0.94(P<0.001)。

关键数值与推荐

  • ΔLVOTarea = RDAVR框架宽度减去由横截面积计算的平均LVOT直径。
  • index Annlong = RDAVR尺寸除以主动脉瓣环最长直径。
  • CAVB预测:ΔLVOTarea比值比2.05(95%CI 1.28-3.30),AUC 0.78(P=0.005),阈值<1.3时概率<3%。
  • PVL预测:index Annlong比值比0.64(95%CI 0.51-0.79),AUC 0.94(P<0.001)。

临床怎么用

  • 术前CT评估主动脉瓣环与LVOT尺寸,避免假体相对LVOT过大以降低CAVB风险。
  • 避免假体相对主动脉瓣环过小以降低PVL风险。
  • 依据CT参数个体化选择RDAVR假体尺寸。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Complications like complete atrioventricular block (CAVB) and paravalvular leakage (PVL) following rapid deployment aortic valve (AV) replacement (RDAVR) remain unresolved. Selecting an optimal size of the valve might be important to minimize the incidence of these complications. We sought to determine the impact of prosthesis size relative to the anatomic profile of the AV on the occurrence of CAVB or PVL after RDAVR. METHODS: Preoperative computed tomographic (CT) images were evaluated in patients receiving RDAVR (INTUITY ELITE) between February 2016 and December 2019. The occurrence of CAVB requiring permanent pacemaker implantation and PVL (≥ mild) was evaluated. The relative size of implants against the cross-sectional dimensions of recipients' AV annulus and left ventricular outflow tract (LVOT) were calculated. RESULTS: Among 187 eligible patients, CAVB and PVL (≥ mild) occurred in 12 (6.4%) and 11 patients (5.9%), respectively. CAVB was associated with oversized RDAVR (RDAVR frame width minus average diameter of LVOT calculated from the cross-sectional area [ΔLVOTarea]: odds ratio, 2.05; 95% confidence interval, 1.28-3.30): this was with an area under the curve of 0.78 (P = 0.005). The projected probability of CAVB was <3% when the ΔLVOTarea was <1.3. In contrast, PVL was associated with under-sized RDAVR (RDAVR size divided by the longest diameter of AV annulus [index Annlong]: odds ratio, 0.64; 95% confidence interval, 0.51-0.79): This was with an area under curve of 0.94 (P < 0.001). CONCLUSIONS: CT parameters of the AV annulus and LVOT are highly reliable in the prediction of CAVB or PVL after RDAVR. Our data might justify CT-based sizing of prosthesis for RDAVR.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Park SJ, Rhee Y, Lee CH, et al. 3-Dimensional computed tomographic assessment predicts conduction block and paravalvular leakage after rapid-deployment aortic valve replacement. Eur J Cardiothorac Surg. 2022. PMID: 34687534. doi:10.1093/ejcts/ezab431

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。