引流淀粉酶:检测食管吻合口漏的简便多用途方法
该研究回顾了290例连续接受食管切除术并胃管重建的患者,评估引流淀粉酶检测吻合口漏的准确性是否受合并症、吻合方式或位置影响。结果显示引流淀粉酶在术后第3至7天是吻合口漏的强预测指标,不受新辅助治疗、吻合位置或类型、患者合并症影响,但在当前吸烟者中准确性较低。术后第3、4或5天最大引流淀粉酶值不高于35时检测漏的敏感性为88%,不低于150时诊断漏的特异性为88%。
要点
- 引流淀粉酶在术后第3至7天是食管切除术后吻合口漏的强预测指标。
- 其准确性不受新辅助治疗、吻合位置或类型、患者合并症影响,但活动性吸烟者中准确性较低。
- 术后第3、4或5天最大引流淀粉酶值不高于35检测漏敏感性88%,不低于150诊断漏特异性88%。
核心结论
- 引流淀粉酶是早期检测食管吻合口漏的多用途方法,其准确性不受新辅助治疗、吻合位置或类型、患者合并症影响,但在活动性吸烟者中可能较低。
研究设计与样本
- 回顾性队列研究,纳入290例连续接受食管切除术并胃管重建的患者,收集患者合并症、手术变量和引流淀粉酶数据,以所需干预水平诊断吻合口漏,并进行ROC曲线分析。
主要发现
- 290例食管切除术中53例(18.3%)发生吻合口漏,其中33例(11.4%)为临床显著漏。
- 引流淀粉酶在术后第3至7天是吻合口漏的强预测指标,不受患者合并症、吻合位置或吻合技术影响。
- 在当前吸烟者中诊断漏的准确性较低(AUC 0.530 vs 0.752;P = .006)。
- 术后第3、4或5天最大引流淀粉酶值不高于35检测术后任何时间点漏的敏感性为88%。
- 引流淀粉酶值不低于150诊断漏的特异性为88%。
关键数值与推荐
- 吻合口漏诊断基于所需干预水平,需伤口开放或内镜或手术干预定义为临床显著漏。
- 术后第3、4或5天最大引流淀粉酶值不高于35:检测漏敏感性88%。
- 引流淀粉酶值不低于150:诊断漏特异性88%。
- 当前吸烟者中引流淀粉酶诊断漏的AUC为0.530,非吸烟者为0.752(P = .006)。
临床怎么用
- 食管切除术后第3至7天可监测引流淀粉酶辅助早期发现吻合口漏。
- 术后第3、4或5天引流淀粉酶值不高于35时漏可能性较低,不低于150时漏可能性较高。
- 对活动性吸烟者需注意引流淀粉酶准确性可能下降,应结合其他临床指标判断。
局限性
- 原文未报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Anastomotic leak after esophagectomy is a significant cause of morbidity. Perianastomotic drain amylase is accurate in detecting leaks, but it is unclear whether its accuracy is affected by comorbid conditions, anastomotic method, or anastomotic location. We hypothesized that drain amylase would accurately discriminate leak in a variety of settings. METHODS: We reviewed 290 consecutive patients undergoing esophagectomy with gastric conduit reconstruction. Patient comorbidities, operative variables, and drain amylase were collected. The diagnosis of a leak was based on the level of intervention required, and was characterized as clinically significant if it required wound opening or endoscopic or surgical intervention. Receiver-operating characteristic curves analysis was performed to determine the accuracy of amylase to detect leak for each patient variable. RESULTS: A total of 53 (18.3%) of 290 esophagectomies had an anastomotic leak, of which 33 (11.4%) of 290 were clinically significant. Drain amylase was a strong predictor of anastomotic leak on postoperative day (POD) 3 to POD 7, regardless of patient comorbidities, location of anastomosis, or technique of anastomosis, but was less accurate in the diagnosis of leak in current smokers (area under the receiver-operating characteristic curve, 0.530 vs 0.752; P = .006). A maximum drain amylase value no higher than 35 on POD 3, POD 4, or POD 5 was 88% sensitive in detecting leak at any point postoperatively. A value greater than or equal to 150 was 88% specific in diagnosing leak. CONCLUSIONS: Drain amylase is a versatile method for early detection of anastomotic leaks. Its accuracy is unaffected by neoadjuvant treatment, location or type of anastomosis, or patient comorbidities but may be less accurate in active smokers.
引用
- Linden PA, Towe CW, Worrell SG, et al. Drain Amylase: A Simple and Versatile Method of Detecting Esophageal Anastomotic Leaks. Ann Thorac Surg. 2021. PMID: 34437855. doi:10.1016/j.athoracsur.2021.07.062
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。