儿童失败Fontan循环的临床与血流动力学特征
该嵌套研究纳入2005至2013年间16个中心登记的177例因Fontan失败等待心脏移植的儿童,分为FAL、FRF、FPF和FNH四种表型。结果显示Fontan压力升高比低心输出量更常见,不同表型的等待期和移植后死亡风险存在差异。
要点
- 儿童失败Fontan中Fontan压力升高(66%>15 mmHg)比低心输出量(10%CI<2.2 L/min/m2)更常见。
- FRF表型等待期死亡风险最高(21%),FNH表型移植后死亡风险最高(36%)。
- 不同表型间血流动力学存在细微差异,FPF的Fontan压力最高(中位22 mmHg),FRF的心脏指数最低(中位2.8 L/min/m2)。
核心结论
- 儿童失败Fontan患者中Fontan压力升高比低心输出量更常见。
- 不同表型间存在细微血流动力学差异,等待期和移植后死亡风险因表型而异。
研究设计与样本
- 儿科心脏移植学会的嵌套研究,16个中心贡献2005至2013年间因Fontan失败等待心脏移植的儿童资料。
- 共177例患儿,分为FAL、FRF、FPF和FNH四种互斥表型,随访中位13个月(IQR 4-31)。
主要发现
- 177例中FAL 84例(47%)、FRF 57例(32%)、FNH 22例(12%)、FPF 14例(8%)。
- Fontan压力在FPF最高(中位22,IQR 18-23 mmHg),在FAL最低(中位16,IQR 14-20 mmHg)。
- 心脏指数在FRF最低(中位2.8,IQR 2.3-3.4 L/min/m2)。
- 全队列中66% Fontan压力>15 mmHg,21%>20 mmHg,10%心脏指数<2.2 L/min/m2。
- FRF等待期死亡风险最高(21%),FNH移植后死亡风险最高(36%)。
临床怎么用
- 评估儿童失败Fontan时应关注Fontan压力升高,其比低心输出量更常见。
- 根据表型(FAL、FRF、FPF、FNH)评估等待期和移植后死亡风险,FRF需警惕等待期死亡,FNH需警惕移植后死亡。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To describe the clinical and hemodynamic characteristics of Fontan failure in children listed for heart transplant. METHODS: In a nested study of the Pediatric Heart Transplant Society, 16 centers contributed information on Fontan patients listed for heart transplant between 2005and 2013. Patients were classified into four mutually exclusive phenotypes: Fontan with abnormal lymphatics (FAL), Fontan with reduced systolic function (FRF), Fontan with preserved systolic function (FPF), and Fontan with "normal" hearts (FNH). Primary outcome was waitlist and post-transplant mortality. RESULTS: 177 children listed for transplant were followed over a median 13 (IQR 4-31) months, 84 (47%) were FAL, 57 (32%) FRF, 22 (12%) FNH, and 14 (8%) FPF. Hemodynamic characteristics differed between the 4 groups: Fontan pressure (FP) was most elevated with FPF (median 22, IQR 18-23, mmHg) and lowest with FAL (16, 14-20, mmHg); cardiac index (CI) was lowest with FRF (2.8, 2.3-3.4, L/min/m2). In the entire cohort, 66% had FP >15 mmHg, 21% had FP >20 mmHg, and 10% had CI <2.2 L/min/m2. FRF had the highest risk of waitlist mortality (21%) and FNH had the highest risk of post-transplant mortality (36%). CONCLUSIONS: Elevated Fontan pressure is more common than low cardiac output in pediatric failing Fontan patients listed for transplant. Subtle hemodynamic differences exist between the various phenotypes of pediatric Fontan failure. Waitlist and post-transplant mortality risks differ by phenotype.
引用
- Dykes JC, Rosenthal DN, Bernstein D, et al. Clinical and hemodynamic characteristics of the pediatric failing Fontan. J Heart Lung Transplant. 2021. PMID: 34412962. doi:10.1016/j.healun.2021.07.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。