文献速递主动脉外科

胸主动脉腔内修复中减少或消除主动脉搏动(REAI)的当前趋势调查

Current trends in reduction or elimination of the aortic impulse during stent-graft deployment and balloon moulding during thoracic endovascular aortic repair.
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01

结果显示REAI在升主动脉最常用(86.4%),主动脉弓(69.4%)和降主动脉(56%)递减;快速右室起搏是各段最常用REAI方法(升主动脉90.9%、弓59.2%、降28.0%),其次为药物降压和静脉流入阻断。

要点

  • REAI在升主动脉最常用(86.4%),弓部69.4%,降主动脉56%。
  • 快速右室起搏是升主动脉(90.9%)和弓部(59.2%)首选REAI方法。
  • 降主动脉更常用药物降压(64.0%)作为REAI方法。

核心结论

  • REAI是所有胸主动脉节段TEVAR的基础,使用率从近端(升主动脉)向远端(降主动脉)递减。
  • 快速右室起搏是TEVAR中最常用的REAI方法。
  • 支架类型和塑形球囊类型影响REAI的使用与否。

研究设计与样本

  • 基于互联网平台的问卷调查,每院1名医生,共联系127名医生。

主要发现

  • 常规使用REAI释放支架:升主动脉86.4%,主动脉弓69.4%,降主动脉56%。
  • 根据支架类型决定是否使用REAI:升主动脉13.6%,弓部24.5%,降主动脉24.0%。
  • 不使用REAI释放支架:升主动脉0.0%,弓部3家中心(6.1%),降主动脉10家中心(20%)。
  • REAI方法(升主动脉/弓/降主动脉):快速右室起搏90.9%/59.2%/28.0%;药物降压13.6%/53.1%/64.0%;静脉流入阻断13.6%/14.3%/4.0%。
  • 不采用REAI的常见原因包括尖端捕获和非闭塞释放系统。

关键数值与推荐

  • 常规REAI使用率:升主动脉86.4%,主动脉弓69.4%,降主动脉56%。
  • 快速右室起搏使用率:升主动脉90.9%,主动脉弓59.2%,降主动脉28.0%。
  • 药物降压使用率:升主动脉13.6%,主动脉弓53.1%,降主动脉64.0%。
  • 静脉流入阻断使用率:升主动脉13.6%,主动脉弓14.3%,降主动脉4.0%。

临床怎么用

  • 在升主动脉TEVAR释放支架时常规考虑REAI,首选快速右室起搏。
  • 在降主动脉TEVAR中可根据情况选用药物降压作为REAI方法。
  • 支架类型和塑形球囊选择影响REAI决策,需个体化评估。

局限性

  • 问卷为自我报告,未与临床实际操作进行验证。
  • 调查未报告患者结局或并发症数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: A survey was performed to evaluate the methods used for reduction or elimination of the aortic impulse (REAI) to facilitate precise stent graft placement and balloon moulding during thoracic endovascular aortic repair (TEVAR). METHODS: A total of 127 physicians (1 per hospital) were contacted and asked to fill out a short, comprehensive questionnaire on an internet-based platform. RESULTS: Fifty physicians (39.4%) responded and completed the survey. Routine use of REAI for stent graft deployment is most frequently used in the ascending aorta and less frequently in the aortic arch and the descending aorta (86.4% vs 69.4% vs 56%). Some physicians based the decision of whether to use REAI on the type of stent graft in the respective location (13.6% vs 24.5% vs 24.0%). Stent-graft deployment without REAI, irrespective of the type of stent graft used, was never done in the ascending aorta (0.0%), in 3 centres in the aortic arch (6.1%) and in 10 centres in the descending aorta (20%). The REAI method most frequently used was dependent on the aortic segment (ascending aorta vs aortic arch vs descending aorta) rapid right ventricular pacing (90.9% vs 59.2% vs 28.0%), followed by pharmacological blood pressure reduction (13.6% vs 53.1% vs 64.0%) and venous inflow occlusion (13.6% vs 14.3% vs 4.0%), respectively. Tip capture and non-occlusive deployment systems were frequently quoted as reasons for not using REAI. CONCLUSIONS: REAI is the fundament for TEVAR in all thoracic aortic segments, with a decline in usage from proximal (ascending) to distal (descending). Rapid right ventricular pacing is the preferred REAI method used in TEVAR. Most procedures are performed with the patient under general anaesthesia. The types of stent grafts and moulding balloons used have an impact on the use or non-use of REAI.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Gottardi R, Wyss TR, van den Berg JC, et al. Current trends in reduction or elimination of the aortic impulse during stent-graft deployment and balloon moulding during thoracic endovascular aortic repair. Eur J Cardiothorac Surg. 2021. PMID: 34368834. doi:10.1093/ejcts/ezab275

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。