文献速递主动脉外科

主动脉弓手术中的术中神经生理监测

Intraoperative neurophysiologic monitoring during aortic arch surgery.
PubMed 文献 · J Thorac Cardiovasc Surg · 2021-07-22

该观察性研究分析了2010至2018年563例需低温循环停跳的主动脉弓重建手术,术中监测脑电图和体感诱发电位。结果显示21.1%患者出现监测变化,其手术死亡率和早期不良神经事件更高;体感诱发电位变化与早期不良神经事件独立相关,任何监测变化与手术死亡率相关。

要点

  • 体感诱发电位变化与早期不良神经事件相关(OR 4.68)。
  • 任何术中监测变化与手术死亡率相关(OR 5.82)。
  • 监测异常对不良神经结局阴性预测值为97.1%。

核心结论

  • 主动脉弓重建术中异常神经生理监测事件预示更差的神经结局和手术死亡率。
  • 体感诱发电位可能比脑电图更敏感地预测早期不良神经事件,尤其持续性变化时。
  • 监测异常对不良神经结局的阴性预测值为97.1%。

研究设计与样本

  • 观察性研究,纳入2010至2018年需低温循环停跳的主动脉弓手术患者563例。
  • 术中监测脑电图和体感诱发电位,比较有无监测变化患者的基线和术后结局。
  • 采用多变量逻辑回归分析监测变化与手术死亡率和早期不良神经事件的关联。

主要发现

  • 119例(21.1%)患者出现监测变化,444例(78.9%)无变化。
  • 有监测变化患者手术死亡率22.7% vs 4.3%,早期不良神经事件10.9% vs 2.9%。
  • 体感诱发电位变化与早期不良神经事件相关(OR 4.68;95%CI 1.51-14.56;P=.008),脑电图变化不相关(P=.532)。
  • 持续性体感诱发电位变化与早期不良神经事件相关(OR 4.56;95%CI 1.51-13.77;P=.007),温度相关变化不相关(P=.997)。
  • 任何监测变化与手术死亡率相关(OR 5.82;95%CI 2.72-12.49;P<.001)。

临床怎么用

  • 在主动脉弓重建术中可考虑使用体感诱发电位和脑电图监测辅助预测神经并发症和死亡风险。
  • 体感诱发电位持续性变化可能提示需及时干预以降低早期不良神经事件风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the ability of intraoperative neurophysiologic monitoring (IONM) during aortic arch reconstruction with hypothermic circulatory arrest (HCA) to predict early (<48 hours) adverse neurologic events (ANE; stroke or transient ischemic attack) and operative mortality. METHODS: This was an observational study of aortic arch surgeries requiring HCA from 2010 to 2018. Patients were monitored with electroencephalogram (EEG) and somatosensory evoked potentials (SSEP). Baseline characteristics and postoperative outcomes were compared according to presence or absence of IONM changes, which were defined as any acute variation in SSEP or EEG, compared with baseline. Multivariable logistic regression analysis was used to assess the association of IONM changes with operative mortality and early ANE. RESULTS: A total of 563 patients underwent aortic arch reconstruction with HCA and IONM. Of these, 119 (21.1%) patients had an IONM change, whereas 444 (78.9%) did not. Patients with IONM changes had increased operative mortality (22.7% vs 4.3%) and increased early ANE (10.9% vs 2.9%). In multivariable analysis, SSEP changes were correlated with early ANE (odds ratio [OR], 4.68; 95% confidence interval [CI], 1.51-14.56; P = .008), whereas EEG changes were not (P = .532). Permanent SSEP changes were correlated with early ANE (OR, 4.56; 95% CI, 1.51-13.77; P = .007), whereas temperature-related SSEP changes were not (P = .997). Finally, any IONM change (either SSEP or EEG) was correlated with operative mortality (OR, 5.82; 95% CI, 2.72-12.49; P < .001). CONCLUSIONS: Abnormal IONM events during aortic arch reconstruction with HCA portend worse neurologic outcomes and operative mortality and have a negative predictive value of 97.1%. SSEP might be more sensitive than EEG for predicting early ANE, especially when SSEP changes are permanent.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Sultan I, Brown JA, Serna-Gallegos D, et al. Intraoperative neurophysiologic monitoring during aortic arch surgery. J Thorac Cardiovasc Surg. 2021. PMID: 34384591. doi:10.1016/j.jtcvs.2021.07.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。