二叶式主动脉瓣修复中交界重定位的体外急性模型研究
本研究利用9个猪心建立Sievers 1型二叶式主动脉瓣病理模型,比较原生120°与重定位180°交界构型在再植入术后的跨瓣压差。静息条件下两种构型无显著差异,但在轻度运动条件下120°构型的平均跨主动脉压差显著高于180°构型。提示180°交界重定位在应激状态下可能改善跨瓣压差。
要点
- 静息时120°与180°交界构型的跨瓣压差无显著差异。
- 运动应激下120°构型平均跨瓣压差显著高于180°构型。
- 180°重定位手术更复杂耗时,但可能改善长期结果。
核心结论
- 180°交界重定位在静息急性模型中未改善跨瓣压差,但在应激条件下可能改善。
研究设计与样本
- 使用9个猪心建立Sievers 1型二叶式主动脉瓣病理模型,均行再植入术并分别在原生120°和重定位180°构型下测试。
主要发现
- 静息时平均跨瓣压差120°组为18.6 ± 5,180°组为17.5 ± 4,无统计学显著差异。
- 静息时峰值跨瓣压差120°组为42.8 ± 12.7,180°组为36.3 ± 5.8,无统计学显著差异。
- 轻度运动条件下120°组平均跨主动脉压差为30.1 ± 9.1,显著高于180°组的24.9 ± 3.8(p值0.002)。
临床怎么用
- 对于交界角度<160°的二叶式主动脉瓣修复,180°重定位或可在运动应激下改善血流动力学。
- 该术式更复杂耗时,但可能作为改善长期结果的策略,尤其适用于年轻患者。
局限性
- 研究为体外急性动物模型,样本量小(9个猪心),结论需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Commissural orientation <160° is a recognized risk factor for bicuspid aortic valve repair failure. Based on this observation, repairing this subtype of aortic valve by reorienting the 2 commissures at 180° has recently been proposed. METHODS: Nine porcine hearts with aortic annulus diameters of 25 mm were selected. A pathological model of a Sievers 1 bicuspid aortic valve was obtained by suturing the coaptation line between the left and right leaflets. Each heart underwent reimplantation procedures both in the native (120°) and the reoriented (180°) configuration. After the operation, each sample was tested on a pulse duplicator at rest (heart rate 60 beats per min) and with mild exercise (heart rate 90 beats per min) conditions. RESULTS: No statistically significant difference was noted in mean and peak transvalvular aortic gradients between the 2 configurations at rest (18.6 ± 5 vs 17.5 ± 4 for the mean aortic gradient; 42.8 ± 12.7 vs 36.3 ± 5.8 for the peak aortic gradient) but the group with the 120°-oriented commissures had significantly higher mean transaortic gradients compared to the group with the 180°-oriented commissures at initial exercise stress conditions (30.1 ± 9.1 vs 24.9 ± 3.8; p value 0.002). CONCLUSIONS: The 180° commissural reorientation of the asymmetrical bicuspid aortic valve does not improve the transvalvular aortic gradient in an acute model at rest conditions, but it could do so under stress situations. Even if it is surgically more complex and time-consuming, this approach could be a good strategy to improve long-term results, particularly in young patients.
引用
- Romagnoni C, Contino M, Jaworek M, et al. Commissural repositioning in bicuspid aortic valve repair: an in vitro acute model to explore and explain different results. Eur J Cardiothorac Surg. 2022. PMID: 34363669. doi:10.1093/ejcts/ezab359
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。