文献速递冠心病外科

韩国全国队列研究:非体外循环与体外循环冠脉搭桥的真实世界结局对比

Real-World Outcomes of On- vs Off-pump Coronary Bypass Surgery: Result From Korean Nationwide Cohort.
PubMed 文献 · Ann Thorac Surg · 2021-08-13

经倾向评分匹配后最终分析6483对患者。结果显示,30天校正死亡率两组无显著差异(HR 1.00,95%CI 0.87-1.16),但长期随访(中位5.3年)中非体外循环CABG与更高的死亡风险(HR 1.09,95%CI 1.03-1.15)、心肌梗死风险(HR 1.3,95%CI 1.16-1.45)和再次血运重建风险(HR 1.50,95%CI 1.37-1.63)相关,而卒中风险相似(HR 0.99,95%CI 0.87-1.13)。

要点

  • 非体外循环CABG与更高的长期死亡风险相关(HR 1.09)。
  • 非体外循环CABG与更高的心肌梗死和再次血运重建风险相关。
  • 30天死亡率和卒中风险两组无显著差异。

核心结论

  • 在当代全国性临床实践理赔登记中,非体外循环CABG与比体外循环CABG更高的长期死亡、心肌梗死和再次血运重建风险相关。

研究设计与样本

  • 研究使用韩国国民健康保险服务全国理赔数据库,识别2004至2013年接受单纯CABG的患者。
  • 采用倾向评分匹配和多变量调整组装基线特征相似的队列,最终分析纳入6483对患者。

主要发现

  • 30天校正死亡率非体外循环组与体外循环组无显著差异(HR 1.00;95%CI 0.87-1.16)。
  • 长期随访(100%完整;中位5.3年;最长13.2年)中,非体外循环CABG与更高的死亡风险相关(HR 1.09;95%CI 1.03-1.15)。
  • 非体外循环CABG组心肌梗死风险(HR 1.3;95%CI 1.16-1.45)和再次血运重建风险(HR 1.50;95%CI 1.37-1.63)显著高于体外循环组。
  • 两组卒中风险相似(HR 0.99;95%CI 0.87-1.13)。

临床怎么用

  • 在真实世界临床实践中,选择非体外循环CABG时应权衡其较高的长期死亡、心肌梗死和再次血运重建风险。
  • 非体外循环CABG在30天死亡率和卒中风险方面与体外循环CABG相当。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although several randomized trials have shown conflicting results regarding the comparative effectiveness of on- and off-pump coronary artery bypass grafting (CABG), research on long-term outcomes in large-scale, real-world clinical settings are limited. The study sought to examine the comparative effectiveness of on- and off-pump CABG in a real-world clinical setting. METHODS: Using the nationwide claims database of the Korean National Health Insurance Service, the study identified patients who underwent isolated CABG from 2004 to 2013. Propensity-score matching with multivariable adjustment was used to assemble a cohort of patients with similar baseline characteristics. RESULTS: Among 23 828 patients, 12 639 in the off-pump group (53.0%) and 11 189 in the on-pump group (47.0%) were enrolled. After matching, 6483 pairs were included in the final analysis. At 30 days, there was no significant difference in adjusted mortality between the off- and on-pump groups (hazard ratio [HR], 1.00; 95% CI, 0.87-1.16). During long-term follow-up (100% complete; median, 5.3 years; maximum, 13.2 years), however, off-pump CABG was associated with a higher risk of mortality than on-pump CABG (HR, 1.09; 95% CI, 1.03-1.15). The risks of myocardial infarction (HR, 1.3; 95% CI, 1.16-1.45) and repeat revascularization (HR, 1.50; 95% CI, 1.37-1.63) were also significantly higher in the off-pump CABG group than in the on-pump CABG group, whereas the stroke risk was similar between the groups (HR, 0.99; 95% CI, 0.87-1.13). CONCLUSIONS: In this contemporary, nationwide, clinical practice claim registry, off-pump CABG was associated with higher long-term risks of mortality, myocardial infarction, and repeat revascularization than on-pump CABG.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Park SJ, Jo AJ, Kim HJ, et al. Real-World Outcomes of On- vs Off-pump Coronary Bypass Surgery: Result From Korean Nationwide Cohort. Ann Thorac Surg. 2021. PMID: 34400133. doi:10.1016/j.athoracsur.2021.07.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。