体外与非体外循环冠状动脉旁路移植术后的长期生存
基于2001至2015年Medicare受益人1235089例单纯CABG(非体外209085例,体外1026004例),比较非体外与体外循环CABG的长期死亡风险,并按外科医生手术量分层。全体外科医生中非体外CABG死亡风险显著升高但临床幅度较小;高手术量医生中风险降低,低手术量医生中风险升高。
要点
- 非体外CABG整体长期死亡风险略高于体外CABG,中位生存差异-134天。
- 高手术量医生行非体外CABG风险降低,中位生存差异-84天。
- 低手术量医生行非体外CABG风险升高,中位生存差异-240天。
核心结论
- 非体外CABG与体外CABG相比长期死亡风险显著但临床幅度较小地升高,高手术量医生行非体外CABG时风险降低。
研究设计与样本
- 回顾性队列研究,纳入2001至2015年Medicare受益人单纯CABG共1235089例(非体外209085例,体外1026004例)。
- 采用Kaplan-Meier和log-rank分析,并在逆概率治疗加权前后比较非体外与体外CABG的长期死亡风险。
- 按外科医生手术量分层(高手术量与低手术量)分析长期死亡风险。
主要发现
- 全体外科医生中,非体外CABG与体外CABG相比死亡风险显著升高(中位生存:非体外9.8年 vs 体外10.2年;中位生存差异-134天;log-rank P < .001)。
- Cox回归分析证实外科医生手术量与长期死亡率存在交互作用。
- 高手术量医生中非体外CABG死亡风险降低(中位生存差异-84天;log-rank P < .001)。
- 低手术量医生中非体外CABG死亡风险升高(中位生存差异-240天;log-rank P < .001)。
临床怎么用
- 选择非体外CABG时应考虑外科医生手术量,高手术量医生行非体外CABG长期生存风险较低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Off-pump coronary artery bypass grafting (CABG) may be associated with increased hazard for long-term mortality as compared with on-pump CABG. We sought to evaluate risk-adjusted long-term survival after off-pump and on-pump CABG, particularly among high-volume and low-volume CABG surgeons. METHODS: We evaluated 1,235,089 isolated CABGs (off pump = 209,085; on pump = 1,026,004) performed in Medicare beneficiaries from 2001 to 2015. Long-term hazard for mortality after off-pump versus on-pump CABG was compared with Kaplan-Meier and log-rank analysis among all CABG surgeons as well as among high-volume and low-volume CABG surgeons, before and after inverse probability of treatment weighting to adjust for confounding. RESULTS: Among all surgeons, off-pump CABG was associated with a statistically significant hazard for mortality as compared with on-pump CABG before and after inverse probability of treatment weighting (median survival: off pump 9.8 years vs on pump 10.2 years; difference in median survival -134 days; log-rank P < .001). Cox regression analysis confirmed an interaction between surgeon volume and long-term mortality. The hazard for mortality associated with off-pump CABG was decreased among high-volume surgeons (difference in median survival -84 days; log-rank P < .001) and increased among low-volume surgeons (difference in median survival -240 days; long-rank P < .001). CONCLUSIONS: Off-pump CABG was associated with a significant, but clinically modest, increased hazard for mortality as compared with on-pump CABG. The hazard was reduced when off-pump CABG was performed by high-volume CABG surgeons.
引用
- Squiers JJ, Schaffer JM, Banwait JK, et al. Long-Term Survival After On-Pump and Off-Pump Coronary Artery Bypass Grafting. Ann Thorac Surg. 2021. PMID: 34411544. doi:10.1016/j.athoracsur.2021.07.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。