新生儿Norwood手术中分流类型比较:MBTS与RVPAC
本研究回顾性比较了322例接受Norwood手术的新生儿,其中MBTS组159例、RVPAC组163例。两组在早期死亡、晚期死亡、双向腔肺分流达成率、分流后死亡率、Fontan完成率及远期生存率上均无显著差异。
要点
- MBTS与RVPAC在Norwood术后早期和晚期死亡率无显著差异。
- 两组间双向腔肺分流达成率、Fontan完成率及分期死亡率均无显著差异。
- 中位随访2.6年(最长18.8年)生存率无显著差异。
核心结论
- 在新生儿Norwood手术中,MBTS与RVPAC在早期死亡、分期间丢失及总体生存方面无显著差异。
研究设计与样本
- 回顾性队列研究,纳入2001-2019年单中心322例接受Norwood手术的新生儿,分为MBTS组(159例)和RVPAC组(163例)。
主要发现
- 早期死亡率MBTS组12.6% vs RVPAC组11.0%(P=0.69),晚期死亡率6.9% vs 7.4%(P=0.87)。
- 双向腔肺分流达成率76.1% vs 77.9%(P=0.69),分流后死亡率7.5% vs 12.3%(P=0.15)。
- Fontan完成率52.2% vs 54.0%(P=0.42)。
- Norwood术后0.5、1、3、6年生存率MBTS组分别为77.1%、73.3%、69.1%、67.9%,RVPAC组分别为81.0%、73.8%、67.9%、67.0%(P=0.97)。
临床怎么用
- 对于接受Norwood手术的新生儿,MBTS和RVPAC均是合理选择,可根据个体情况决定。
局限性
- 本研究为单中心回顾性研究,可能存在选择偏倚。
- 随访时间中位2.6年,最长18.8年,远期结果需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The ideal shunt for pulmonary blood flow, modified Blalock-Taussig shunt (MBTS) or right ventricular-pulmonary artery conduit (RVPAC) is yet to be determined. This study aimed to evaluate outcomes after the Norwood procedure according to the type of shunt. METHODS: A total of 322 neonates with hypoplastic left heart syndrome and related anomalies who underwent the Norwood procedure at our institution between 2001 and 2019 were divided into MBTS and RVPAC groups and the outcomes after the Norwood procedure were compared between the groups with respect to mortality after each staged procedure. RESULTS: We identified 322 consequent patients who underwent neonatal Norwood procedure for hypoplastic left heart syndrome (271 patients, 84.2%) and its variant (51 patients, 15.8%). RVPAC was performed in 163 (50.6%) patients and MBTS was performed in 159 (49.4%). There were no differences in the rate of early death (11.0% vs 12.6%, P = 0.69) or late death (7.4% vs 6.9%, P = 0.87) between the 2 groups after the Norwood procedure, and no significant difference in the number of patients who reached bidirectional cavopulmonary shunt (77.9% vs 76.1%, P = 0.69), and there was no difference in mortality after bidirectional cavopulmonary shunt (12.3% vs 7.5%, P = 0.15) or Fontan completion rate (54.0% vs 52.2%, P = 0.42) between the 2 groups. Survival at 0.5, 1, 3 and 6 years after the Norwood procedure was 81.0%, 73.8%, 67.9% and 67.0% in patients with RVPAC and 77.1%, 73.3%, 69.1% and 67.9% in patients with MBTS. There was no significant difference in the survival between the 2 groups during the median follow-up of 2.6 (interquartile ranges: 0.3-8.4, maximal 18.8) years (P = 0.97). CONCLUSIONS: In neonates undergoing the Norwood procedure, our available data of maximal 18.8 years follow-up showed no significant difference in early mortality, inter-stage attritions, or overall survival, between MBTS and RVPAC.
引用
- Ono M, Kido T, Wallner M, et al. Comparison of shunt types in the neonatal Norwood procedure for single ventricle. Eur J Cardiothorac Surg. 2021. PMID: 34050665. doi:10.1093/ejcts/ezab163
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。