文献速递主动脉外科

Relay Branch系统腔内修复主动脉弓的结果

Results of endovascular aortic arch repair using the Relay Branch system.
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01

院内死亡率为9%,致残性卒中7%,非致残性卒中19%,早期IA/B型内漏4%。随访中23%患者死亡,主动脉相关死亡低。结论认为技术成功率好,非致残性卒中为主要关注点,残余主动脉夹层患者预后最佳。

要点

  • Relay Branch系统腔内修复主动脉弓技术成功率好,院内死亡率9%。
  • 非致残性卒中发生率达19%,是主要关注点。
  • 残余主动脉夹层患者预后最佳,院内死亡和致残性卒中均为0%。

核心结论

  • Relay Branch系统在选定患者中技术成功率高,院内死亡可接受,致残性卒中少,但非致残性卒中需重视。
  • 残余主动脉夹层患者结局最佳,仍需更多数据。

研究设计与样本

  • 评估指标包括院内死亡、神经损伤、技术成功和二次干预需求,并按病变类型(非夹层病变 vs 残余主动脉夹层)分析。

主要发现

  • 院内死亡率为9%,残余主动脉夹层患者为0%。
  • 致残性卒中发生率为7%(残余主动脉夹层患者0%),非致残性卒中为19%(残余主动脉夹层患者7%)。
  • 早期IA和B型内漏发生率为4%。
  • 中位随访16±18个月,随访期间23%患者死亡,主动脉相关死亡低(残余主动脉夹层患者3%)。

临床怎么用

  • 对于选定累及主动脉弓的胸主动脉病变患者,可考虑使用Relay Branch系统进行腔内修复。
  • 应特别关注并尽力减少非致残性卒中的发生。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Our goal was to evaluate results of endovascular aortic arch repair using the Relay Branch system. METHODS: Forty-three patients with thoracic aortic pathology involving the aortic arch have been treated with the Relay Branch system (Terumo Aortic, Sunrise, FL, USA) in 10 centres. We assessed in-hospital mortality, neurological injury, treatment success according to current reporting standards and the need for secondary interventions. In addition, outcome was analysed according to the underlying pathology: non-dissective disease versus residual aortic dissection (RAD) (defined as remaining dissection after previous type A repair, chronic type B aortic dissections). RESULTS: In-hospital mortality was 9% (0% in patients with RAD). Disabling stroke occurred in 7% (0% in patients with RAD); non-disabling stroke occurred in 19% (7% in patients with RAD). Early type IA and B endoleak formation occurred in 4%. Median follow-up was 16 ± 18 months. During the follow-up period, 23% of the patients died. Aortic-related deaths were low (3% in patients with RAD). CONCLUSIONS: The results of endovascular aortic arch repair using the Relay Branch system in a selected patient population with regard to technical success are good. In-hospital mortality is acceptable, the number of disabling strokes is low and technical success is high. Non-disabling stroke is a major concern, and every effort has to be taken to reduce this to a minimum. The best outcome is seen in patients with underlying RAD. Finally, more data are needed.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Czerny M, Berger T, Kondov S, et al. Results of endovascular aortic arch repair using the Relay Branch system. Eur J Cardiothorac Surg. 2021. PMID: 33956958. doi:10.1093/ejcts/ezab160

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。