快速蒸发电离质谱(智能刀)用于主动脉外科即时检测的探索

Exploring the potential of rapid evaporative ionization mass spectrometry (Intelligent Knife) for point-of-care testing in aortic surgery.
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01

本研究为横断面研究,采用快速蒸发电离质谱(REIMS)分析电外科气溶胶,对44例胸主动脉瘤患者的离体主动脉组织与13例正常主动脉进行判别。结果显示模型区分动脉瘤与正常主动脉的准确率和精确率分别为88.7%和85.1%,并可按二叶式与三叶式主动脉瓣进一步区分,支持该技术作为指导术中决策的即时检测工具开发。

要点

  • REIMS分析电外科气溶胶可区分动脉瘤性与正常胸主动脉。
  • 模型总体准确率88.7%、精确率85.1%。
  • 按瓣膜类型分层后仍可区分正常、二叶式与三叶式主动脉组织。

核心结论

  • REIMS分析离体主动脉组织的电外科气溶胶可区分动脉瘤性与正常主动脉,支持其作为指导术中决策的即时检测(智能刀)进行开发。

研究设计与样本

  • 横断面研究;胸主动脉瘤手术患者主动脉组织n=44,正常主动脉来自尸检与冠状动脉手术患者的穿刺活检共n=13。
  • 对样本施加单极电灼,抽吸手术气溶胶并以REIMS分析获得质谱数据。

主要发现

  • REIMS数据生成的模型区分动脉瘤性与正常主动脉的准确率为88.7%,精确率为85.1%。
  • 进一步分析中,区分正常组织、二叶式主动脉瓣与三叶式主动脉瓣动脉瘤组织的准确率分别为93.5%、83.8%、89.3%,精确率分别为91.4%、76.7%、86.0%。

关键数值与推荐

  • 区分动脉瘤与正常主动脉:准确率88.7%,精确率85.1%。
  • 正常对照:准确率93.5%,精确率91.4%。
  • 二叶式主动脉瓣组:准确率83.8%,精确率76.7%。
  • 三叶式主动脉瓣组:准确率89.3%,精确率86.0%。

临床怎么用

  • 该技术有望作为即时检测工具,辅助术中判断主动脉病变范围与手术决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Many intraoperative decisions regarding the extent of thoracic aortic surgery are subjective and are based on the appearance of the aorta, perceived surgical risks and likelihood of early recurrent disease. Our objective in this work was to carry out a cross-sectional study to demonstrate that rapid evaporative ionization mass spectrometry (REIMS) of electrosurgical aerosol is able to empirically discriminate ex vivo aneurysmal human thoracic aorta from normal aorta, thus providing supportive evidence for the development of the technique as a point-of-care test guiding intraoperative surgical decision-making. METHODS: Human aortic tissue was obtained from patients undergoing surgery for thoracic aortic aneurysms (n = 44). Normal aorta was obtained from a mixture of post-mortem and punch biopsies from patients undergoing coronary surgery (n = 13). Monopolar electrocautery was applied to samples and surgical aerosol aspirated and analysed by REIMS to produce mass spectral data. RESULTS: Models generated from REIMS data can discriminate aneurysmal from normal aorta with accuracy and precision of 88.7% and 85.1%, respectively. In addition, further analysis investigating aneurysmal tissue from patients with bicuspid and tricuspid aortic valves was discriminated from normal tissue and each other with accuracies and precision of 93.5% and 91.4% for control, 83.8% and 76.7% for bicuspid aortic valve and 89.3% and 86.0% for tricuspid aortic valve, respectively. CONCLUSIONS: Analysis of electrosurgical aerosol from ex vivo aortic tissue using REIMS allowed us to discriminate aneurysmal from normal aorta, supporting its development as a point-of-care test (Intelligent Knife) for guiding surgical intraoperative decision-making.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Davies HA, Caamano-Gutierrez E, Sarsby J, et al. Exploring the potential of rapid evaporative ionization mass spectrometry (Intelligent Knife) for point-of-care testing in aortic surgery. Eur J Cardiothorac Surg. 2021. PMID: 33842942. doi:10.1093/ejcts/ezab166

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。