文献速递瓣膜外科

Edwards Intuity快速部署瓣主动脉瓣置换术后传导异常恢复情况

Recovery From Conduction Abnormalities After Aortic Valve Replacement Using Edwards Intuity.
PubMed 文献 · Ann Thorac Surg · 2021-04-24

本研究纳入167例使用Edwards Intuity瓣行快速部署主动脉瓣置换术的患者,分析术后各类传导异常的发生率及时间变化。术后三度房室传导阻滞发生率为10.8%,其中15例在中位术后10天恢复窦性心律;左或右束支传导阻滞发生率为40.1%,其中44例在中位术后12天恢复原节律;迟发性传导异常发生率为21.0%,其中28例自行消退。结论认为传导异常发生率高但多数可自行恢复,可能与植入技术有关。

要点

  • 快速部署主动脉瓣置换术后三度房室传导阻滞发生率为10.8%,多数可恢复窦性心律。
  • 左或右束支传导阻滞发生率为40.1%,中位12天部分恢复原节律。
  • 迟发性传导异常发生率为21.0%,多数可自行消退。

核心结论

  • 快速部署主动脉瓣置换术后传导异常发生率高,但大多数可自行恢复,良好结果可能归因于本研究的植入技术。

研究设计与样本

  • 回顾性分析167例在研究期间接受快速部署主动脉瓣置换术的患者,评估术后传导异常的发生率及时间变化。

主要发现

  • 术后三度房室传导阻滞发生于18例(10.8%),其中15例在中位术后10天恢复窦性心律。
  • 左或右束支传导阻滞发生于67例(40.1%),其中44例在中位术后12天恢复原节律。
  • 迟发性传导异常发生于35例(21.0%),中位术后第4天出现,其中28例自行消退。

临床怎么用

  • 术后应监测传导异常,但多数可自行恢复,无需过早干预。
  • 采用额外锚定缝线和5-mm视频镜实现完全环贴合可能有助于改善传导异常恢复。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study investigated the incidences of various conduction abnormalities after rapid-deployment aortic valve replacement using Edwards Intuity (Edwards Lifesciences, Irvine, CA) valve and the temporal changes of these abnormalities during the postoperative course. DESCRIPTION: We modified the procedure by placing additional anchoring sutures and using a 5-mm videoscope to achieve "complete annulus fitting." Direct visual inspection by videoscopy inside and outside the valve guaranteed complete annulus fitting. EVALUATION: Overall 167 patients who underwent rapid-deployment aortic valve replacement during the study period were included in the analysis of postoperative conduction abnormalities. After rapid-deployment aortic valve replacement, third-degree atrioventricular block occurred in 18 patients (10.8%), but 15 patients recovered to sinus rhythm at median postoperative 10 days. Left or right bundle branch block occurred in 67 patients (40.1%), but 44 patients returned to their original rhythm at median postoperative 12 days. Delayed-onset conduction abnormalities occurred in 35 patients (21.0%) at median postoperative day 4, and spontaneously regressed in 28 patients. CONCLUSIONS: The incidence of conduction abnormalities after rapid-deployment aortic valve replacement was high, but most of these abnormalities spontaneously recovered. These good results may be attributed to our implantation technique.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Sohn SH, Kim KH, Kang Y, et al. Recovery From Conduction Abnormalities After Aortic Valve Replacement Using Edwards Intuity. Ann Thorac Surg. 2021. PMID: 33905729. doi:10.1016/j.athoracsur.2021.04.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。