文献速递瓣膜外科

低危患者无支架与缝合式主动脉瓣置换比较

Surgical Sutureless and Sutured Aortic Valve Replacement in Low-risk Patients.
PubMed 文献 · Ann Thorac Surg · 2021-03-29

基于Evolut低危试验,比较无支架与缝合式外科主动脉瓣置换。两组30天安全复合终点相似,但无支架组起搏器植入和瓣膜相关住院更高。

要点

  • 无支架与缝合瓣30天安全复合终点相似(10.8% vs 11.0%)
  • 无支架组30天永久起搏器植入显著更高(14.4% vs 2.9%)
  • 无支架组1年瓣膜相关住院更多(9.1% vs 5.1%)

核心结论

  • 低危患者中无支架瓣未在30天并发症上显示获益,血流动力学略优但起搏器植入和瓣膜相关住院增加。

研究设计与样本

  • Evolut低危试验中随机接受自膨胀经导管主动脉瓣置换或外科主动脉瓣置换,外科组使用无支架或缝合瓣由术者决定。

主要发现

  • 30天安全复合终点无支架组10.8% vs 缝合组11.0%(P=.93)。
  • 30天全因死亡0.5% vs 1.5%(P=.28),1年3.3% vs 2.6%(P=.74)。
  • 30天致残性卒中2.0% vs 1.5%(P=.65),1年2.6% vs 2.2%(P=.76)。
  • 30天永久起搏器植入14.4% vs 2.9%(P<.001),1年瓣膜相关住院9.1% vs 5.1%(P=.04)。

关键数值与推荐

  • 1年平均跨瓣压差无支架组9.9±4.2 mmHg vs 缝合组11.7±4.7 mmHg(P<.001)。

临床怎么用

  • 低危患者选择无支架瓣需权衡起搏器植入和瓣膜相关住院风险,血流动力学获益有限。

局限性

  • 瓣膜类型选择非随机,由术者决定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Randomized clinical trials have shown that transcatheter aortic valve replacement is noninferior to surgery in low surgical risk patients. We compared outcomes in patients treated with a sutured (stented or stentless) or sutureless surgical valve from the Evolut Low Risk Trial. METHODS: The Evolut Low Risk Trial enrolled patients with severe aortic stenosis and low surgical risk. Patients were randomized to self-expanding transcatheter aortic valve replacement or surgery. Use of sutureless or sutured valves was at the surgeons' discretion. RESULTS: Six hundred eighty patients underwent surgical aortic valve implantation (205 sutureless, 475 sutured). The Valve Academic Research Consortium-2 30-day safety composite endpoint was similar in the sutureless and sutured group (10.8% vs 11.0%, P = .93). All-cause mortality between groups was similar at 30 days (0.5% vs 1.5%, P = .28) and 1 year (3.3% vs 2.6%, P = .74). Disabling stroke was also similar at 30 days (2.0% vs 1.5%, P = .65) and 1 year (2.6% vs 2.2%, P = .76). Permanent pacemaker implantation at 30 days was significantly higher in the sutureless compared with the sutured group (14.4% vs 2.9%, P < .001). Aortic valve-related hospitalizations occurred more often at 1 year with sutureless valves (9.1% vs 5.1%, P = .04). Mean gradients 1 year after sutureless and sutured aortic valve replacement were 9.9 ± 4.2 versus 11.7 ± 4.7 mm Hg (P < .001). CONCLUSIONS: Among low-risk patients, sutureless versus sutured valve use did not demonstrate a benefit in terms of 30-day complications and produced marginally better hemodynamics but with an increased rate of pacemaker implantation and valve-related hospitalizations.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Lam KY, Reardon MJ, Yakubov SJ, et al. Surgical Sutureless and Sutured Aortic Valve Replacement in Low-risk Patients. Ann Thorac Surg. 2021. PMID: 33794164. doi:10.1016/j.athoracsur.2021.03.048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。