文献速递主动脉外科瓣膜外科

三叶式主动脉瓣主动脉瘤比单叶式主动脉瓣主动脉瘤退变更重

Aortic aneurysms with tricuspid aortic valve have more degeneration than unicuspid aortic valve aneurysms.
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01

该回顾性观察研究分析了74份术中获取的升主动脉壁标本,比较单叶式主动脉瓣(UAV)与三叶式主动脉瓣(TAV)患者扩张与非扩张主动脉的壁结构变化。结果显示UAV主动脉瘤凋亡增加,但TAV扩张标本的黏蛋白样细胞外基质积聚(MEMA)分布和严重程度更高,提示UAV相关主动脉瘤可能侵袭性更低。

要点

  • UAV主动脉瘤凋亡较TAV更明显,但TAV扩张主动脉MEMA更重。
  • 无论瓣膜形态,扩张主动脉均见平滑肌细胞核丢失增加和穿板层MEMA。
  • UAV相关主动脉瘤的壁改变可能较TAV相关者侵袭性更低。

核心结论

  • UAV主动脉瘤显示凋亡增加,其作用尚不明确。
  • TAV主动脉瘤的MEMA严重程度高于UAV主动脉瘤,提示UAV相关主动脉瘤可能侵袭性更低。

研究设计与样本

  • 回顾性观察研究,纳入74份术中获取的升主动脉壁标本,包括扩张与非扩张主动脉、UAV与TAV个体。
  • 采用标准染色及免疫组化标记cleaved caspase-3、CD31和eNOS,评估凋亡、eNOS分布、平滑肌细胞核丢失和MEMA。

主要发现

  • 扩张主动脉中血管滋养管侵入更深,eNOS主要表达于血管滋养管。
  • UAV主动脉凋亡多于TAV主动脉(P < 0.001)。
  • UAV与TAV主动脉平滑肌细胞核丢失相当(P = 0.419)。
  • 扩张较非扩张主动脉平滑肌细胞核丢失增加(P = 0.005),穿板层MEMA更明显(P = 0.011)。
  • TAV扩张标本MEMA分布最高分级(P = 0.043)和最高严重程度(P = 0.005)均见于与UAV扩张标本比较。

临床怎么用

  • UAV相关主动脉瘤的壁退变可能较TAV相关者轻,临床随访策略可参考此差异。
  • TAV扩张主动脉MEMA更重,提示需关注其主动脉壁退变程度。

局限性

  • 原文未报告样本量以外的具体局限性信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The unicuspid aortic valve (UAV) is a rare cardiac malformation and is associated with the formation of ascending aortic aneurysms. To characterize its associated aortic wall changes, normal and aneurysmatic ascending aortic wall specimens were analysed, focusing on the potential mechanisms of aneurysm formation. Patients with tricuspid aortic valve (TAV) served as controls. METHODS: In a retrospective observational study, 74 specimens (dilated and non-dilated aortas; individuals with UAV and TAV) obtained intraoperatively were studied. Standard stains and immunohistochemical labelling of cleaved caspase-3, cluster of differentiation 31 and endothelial nitric oxide synthase (eNOS) were performed to assess the degree of apoptosis, distribution of eNOS within the aortic wall, smooth muscle cell (SMC) nuclei loss and mucoid extracellular matrix accumulation (MEMA). RESULTS: Deeper ingrowth of vasa vasorum was found in dilated aortas. Interestingly, eNOS was expressed mostly in vasa vasorum. More apoptosis was seen in UAV aortas compared to TAV aortas (P < 0.001). Both UAV and TAV aortas were comparable regarding SMC nuclei loss (P = 0.419). In dilated compared to non-dilated aortas regardless valve morphology SMC nuclei loss was increased (P = 0.005) and more pronounced translamellar MEMA was present (P = 0.011). The highest grade of distribution (P = 0.043) and the highest severity (P = 0.005) regarding MEMA were seen in TAV dilated specimens compared to UAV dilated specimens. CONCLUSIONS: Aneurysms with UAV show increased apoptosis, the role of which is unclear. Strikingly, more severe MEMA was found in TAV aneurysms compared to UAV aneurysms. Thus, UAV-associated aortic wall changes and resulting aneurysm may be less aggressive than aneurysms with TAV.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Federspiel JM, Schnabel PA, Tschernig T, et al. Aortic aneurysms with tricuspid aortic valve have more degeneration than unicuspid aortic valve aneurysms. Eur J Cardiothorac Surg. 2021. PMID: 33675640. doi:10.1093/ejcts/ezab101

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。