窦部折叠术在二叶式主动脉瓣成形术中的疗效:搏动流模拟模型实验
本研究利用搏动流模拟器和基于CT数据构建的二叶式主动脉瓣(BAV)体外模型,评估窦部折叠术的血流动力学效应。结果显示,窦部折叠术可显著增加非融合瓣叶角度,有效控制反流并改善瓣膜开放。
要点
- 窦部折叠术显著增加BAV模型非融合瓣叶角度。
- 窦部折叠术降低跨瓣压差和反流分数。
- 窦部折叠术增加平均流量,改善瓣膜开放。
核心结论
- 窦部折叠术在BAV模型中显著增加连合角度,有效控制反流并改善瓣膜开放。
研究设计与样本
- 基于BAV患者CT数据,用牛心包和血管假体(J-graft Shield Neo Valsalva 24 mm)构建BAV模型(对照组n=6),并实施窦部折叠术(SP组n=6),在搏动流模拟器中比较血流动力学数据。
主要发现
- SP组平均流量显著高于对照组(4.24 ± 0.14 l/min vs 4.14 ± 0.15 l/min,P = 0.034)。
- SP组平均跨瓣压差显著低于对照组(11.6 ± 4.3 mmHg vs 16.6 ± 5.0 mmHg,P = 0.009)。
- SP组反流分数显著低于对照组(14.1 ± 2.0% vs 17.4 ± 2.1%,P = 0.001)。
- 超声测量显示SP组非融合瓣叶角度显著大于对照组(163.8° ± 9.2° vs 153.0° ± 4.6°,P = 0.012)。
临床怎么用
- 窦部折叠术可能作为BAV成形术的辅助技术,有助于稳定瓣膜并改善血流动力学。
局限性
- 研究为体外模拟实验,需未来研究评估瓣叶应力及长期耐久性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Sinus plication has emerged as a promising tool that can lead to better stability in bicuspid aortic valve (BAV) repair. However, the mechanisms underlying the efficacy of this technique are unclear. We evaluated the hydrodynamic effect of sinus plication using the experimental pulsatile flow simulator and our original BAV model in vitro. METHODS: Based on the computed tomography data of a BAV patient who had undergone aortic valvuloplasty, a BAV model (group C, n = 6) was developed with bovine pericardium and vascular prosthesis (J-graft Shield Neo Valsalva 24 mm). We performed sinus plication (group SP, n = 6) in the BAV model and compared hydrodynamic data with the control model in the pulsatile flow simulator. Non-fused cusp angle, annulus diameter and effective height were measured by ultrasonography. RESULTS: The average flow was significantly increased in group SP compared to group C (4.24 ± 0.14 l/min vs 4.14 ± 0.15 l/min, respectively, P = 0.034). The mean transvalvular pressure gradient and regurgitant fraction were significantly decreased in group SP compared to group C (11.6 ± 4.3 mmHg vs 16.6 ± 5.0 mmHg, respectively, P = 0.009 and 14.1 ± 2.0% vs 17.4 ± 2.1%, respectively, P = 0.001). Ultrasound measurement indicated that non-fused cusp angle was significantly increased in group SP compared to group C (163.8° ± 9.2° vs 153.0° ± 4.6°, respectively, P = 0.012). CONCLUSIONS: Sinus plication in the BAV model significantly increased the commissural angle. It was effective in not only controlling regurgitation but also improving valve opening. These finding should be confirmed by evaluating cusp stress and/or long-term durability in the future studies.
引用
- Arimura S, Takada J, Nishimura G, et al. The efficacy of sinus plication in aortic valvuloplasty for bicuspid aortic valve: experiments in a pulsatile flow simulation model. Eur J Cardiothorac Surg. 2021. PMID: 33760025. doi:10.1093/ejcts/ezab115