右位心合并主动脉瓣反流与二尖瓣反流患者的复杂经导管治疗一例
70岁女性,症状性重度原生主动脉瓣反流、获得性右位心、中重度继发性二尖瓣反流且外科风险禁忌,行经导管主动脉瓣置换术成功植入球囊扩张式Sapien 3 Ultra瓣膜。6个月后因二尖瓣反流仍症状明显,行经导管二尖瓣修复术使用Carillon Mitral Contour System,二尖瓣反流显著减少,随访无事件。
要点
- 首例在原生主动脉瓣反流、获得性右位心及严重主动脉瓣环旋转不良患者中使用球囊扩张式瓣膜行TAVR。
- 首例由心脏外科医生使用Carillon装置行经导管二尖瓣修复术。
- 因经食管超声引导不可行,其他经导管修复技术不可行。
核心结论
- 在解剖复杂(获得性右位心、主动脉瓣环严重旋转不良)且外科禁忌的患者中,球囊扩张式瓣膜TAVR及Carillon经导管二尖瓣修复术可行。
研究设计与样本
- 单例病例报告:70岁女性,症状性重度原生主动脉瓣反流、获得性右位心、中重度继发性二尖瓣反流,外科手术风险禁忌。
主要发现
- 成功植入球囊扩张式Sapien 3 Ultra瓣膜行TAVR。
- 6个月后因中重度继发性二尖瓣反流仍症状明显,行Carillon Mitral Contour System经导管二尖瓣修复术。
- 术后二尖瓣反流显著减少,随访无事件。
临床怎么用
- 对于外科禁忌的复杂解剖(右位心、瓣环旋转不良)主动脉瓣反流患者,可考虑球囊扩张式瓣膜TAVR。
- 当经食管超声引导不可行时,Carillon装置经导管二尖瓣修复术可作为选择。
局限性
- 单例病例报告,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
A 70-year-old female with symptomatic severe native aortic regurgitation, acquired dextrocardia, moderate-to-severe secondary mitral regurgitation and prohibitive surgical risk was admitted for transcatheter aortic valve replacement. A balloon-expendable Sapien 3 Ultra valve was implanted successfully. After 6 months, the patient remained symptomatic due to the concomitant moderate-to-severe secondary mitral regurgitation. Transcatheter mitral valve repair using a Carillon Mitral Contour System was performed resulting in a significant reduction of mitral regurgitation and uneventful follow-up. Most importantly, other transcatheter repair techniques would not have been feasible due to the impossible transoesophageal echocardiography guidance. This is the first case of transcatheter aortic valve replacement in a patient with native aortic regurgitation, acquired dextrocardia and severe aortic annulus malrotation using a balloon-expendable valve. Moreover, it is the first transcatheter mitral valve repair procedure using Carillon device performed by a cardiac surgeon.
引用
- Rudziński PN, Mach M, Gross C, et al. Complex transcatheter aortic valve replacement in aortic regurgitation and transcatheter mitral annuloplasty in severe dextrocardia. Eur J Cardiothorac Surg. 2021. PMID: 33709153. doi:10.1093/ejcts/ezab124