文献速递瓣膜外科

三维成形环三尖瓣成形术的长期结果:有效且持久

Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: effective and durable!
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01

该回顾性研究分析了2011至2014年间168例使用三维成形环行三尖瓣成形的患者,中位年龄66岁,49%为NYHA III-IV级,60%合并房颤。7年心脏死亡累积发生率为1.9±1.1%,三尖瓣反流≥2+复发累积发生率为14±3.17%,两种成形环间无显著差异(P=0.3),房颤是复发的唯一独立预测因子。

要点

  • 三维成形环三尖瓣成形术后7年三尖瓣反流≥2+复发率较低(14±3.17%)。
  • Medtronic 3D Contour与Edwards MC3环的7年反流复发无显著差异(P=0.3)。
  • 房颤是三尖瓣反流≥2+复发的唯一独立预测因子。

核心结论

  • 三维成形环三尖瓣成形术有效且持久,7年三尖瓣反流复发率相对较低且多为中度。
  • 房颤作为三尖瓣反流复发的预测因素得到确认。

研究设计与样本

  • 采用Kaplan-Meier法分析长期生存,以死亡为竞争结局的累积发生函数估计心脏死亡。

主要发现

  • 中位年龄66岁,82例(49%)为NYHA III-IV级,101例(60%)合并房颤,中位射血分数60%。
  • 82例(49%)使用Medtronic 3D Contour环,86例(51%)使用Edwards MC3环。
  • 7年心脏死亡累积发生率为1.9±1.1%(95%CI 0.51-4.95)。
  • 7年三尖瓣反流≥2+复发累积发生率为14±3.17%(95%CI 8.49-20.82)。
  • 7年三尖瓣反流≥2+复发在两种成形环间无显著差异(P=0.3)。

关键数值与推荐

  • 7年心脏死亡累积发生率1.9±1.1%(95%CI 0.51-4.95)。
  • 7年三尖瓣反流≥2+复发累积发生率14±3.17%(95%CI 8.49-20.82)。
  • 两种成形环7年反流复发比较P=0.3。

临床怎么用

  • 三维成形环可用于三尖瓣成形,长期效果有效且持久。
  • 合并房颤患者术后需关注三尖瓣反流复发风险。
  • Medtronic 3D Contour与Edwards MC3环在7年反流复发方面效果相当。

局限性

  • 回顾性研究设计。
  • 样本量有限(168例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: 3-Dimensional (3D)-shaped rings are largely adopted for tricuspid annuloplasty, but evidence about their long-term results is scanty. The goal of this study was to analyse the long-term results of tricuspid annuloplasty with 3D-shaped rings. MATERIALS AND METHODS: A retrospective review of our prospectively maintained database was carried out to identify all patients who underwent tricuspid valve repair with 3D-shaped rings between January 2011 and December 2014. Kaplan-Meier methods were used to analyse long-term survival. Cumulative incidence function using death as the competitive outcome was used to estimate cardiac death. RESULTS: A total of 168 patients were identified. The median age was 66 years. Eighty-two patients (49%) were in advanced New York Heart Association functional class III-IV. Atrial fibrillation (AF) was present in 101 (60%); the median ejection fraction was 60%. In 82 (49%) patients, a Medtronic 3D Contour annuloplasty ring was employed; in the remaining 86 (51%) patients, an Edwards MC3 ring was used. Cumulative incidence function of cardiac death, with non-cardiac death as a competing risk, was 1.9 ± 1.1%, 95% confidence interval (CI) (0.51-4.95) at 7 years. The cumulative incidence function of recurrence of tricuspid regurgitation (TR) ≥2+ at 7 years was 14 ± 3.17%, 95% CI (8.49-20.82). Recurrence of TR ≥2+ at 7 years was not significantly different between the Medtronic 3D Contour and the Edwards MC3 rings (P = 0.3). AF was identified as the only independent predictor of recurrence of TR ≥2+. CONCLUSIONS: 3D-shaped rings are effective and durable. TR recurrence was relatively low at 7 years and usually moderate (2+/4+) without a significant difference between the 2 types of rings. The role of AF as a predictor of TR recurrence was confirmed.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Carino D, Zancanaro E, Lapenna E, et al. Long-term results of tricuspid annuloplasty with 3-dimensional-shaped rings: effective and durable! Eur J Cardiothorac Surg. 2021. PMID: 33693644. doi:10.1093/ejcts/ezab111

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。