文献速递心外重症与机械循环支持

持久机械循环支持心衰患者运动中的右室功能与心肺表现

Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices.
PubMed 文献 · J Heart Lung Transplant · 2020-11-22

研究纳入26例连续流左室辅助装置(CF-LVAD)患者,分为右室压力-容积环组和Swan-Ganz导管组,在侵入性心肺运动试验中评估右室功能与整体心肺表现。结果显示CF-LVAD患者右室收缩储备有限,运动时肺动脉压、左心充盈压和右心充盈压显著升高,通气效率严重异常,这些机制解释了功能容量持续下降的原因。

要点

  • CF-LVAD患者右室收缩储备有限,峰值运动时收缩力无明显增加。
  • 运动时肺动脉压、左心和右心充盈压显著升高。
  • 通气效率严重异常(42.3±11.6),可能解释功能容量下降。

核心结论

  • CF-LVAD患者存在右室收缩储备有限、运动时肺及左右心充盈压显著升高和严重通气效率异常,这些发现解释了该人群功能容量持续下降的机制。

研究设计与样本

  • 研究纳入26例CF-LVAD患者(年龄58±11岁,23例男性),完成侵入性心肺运动试验。
  • Group 1(n=13)置入右室 conductance 导管生成压力-容积环,Group 2(n=13)使用传统Swan-Ganz导管。
  • 在静息、2个次极量运动水平和峰值运动时采集血流动力学,并通过间接测热法收集逐口气体交换参数。
  • Group 1参与者还在仰卧静息时完成侵入性斜坡测试,以确定不同CF-LVAD支持水平对右室功能的影响。

主要发现

  • Group 1中,泵速调节对右室功能影响极小。
  • 直立运动时,次极量运动期间右室收缩力有适度增加,但峰值运动时无明显增加。
  • 整个运动过程中,心室-动脉耦联保持良好。
  • Group 2中,次极量和峰值运动时肺动脉压、左心充盈压和右心充盈压大幅升高。
  • 所有参与者中,心输出量-氧摄取关系保持为5.8:1,通气效率严重异常为42.3±11.6。

临床怎么用

  • 临床应关注CF-LVAD患者右室收缩储备有限及运动时充盈压显著升高的现象。
  • 运动时通气效率严重异常提示需评估功能容量下降的通气因素。
  • 泵速调节对右室功能影响极小,不宜仅靠调泵速改善运动右室功能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with continuous-flow left ventricular assist devices (CF-LVADs) experience limitations in functional capacity and frequently, right ventricular (RV) dysfunction. We sought to characterize RV function in the context of global cardiopulmonary performance during exercise in this population. METHODS: A total of 26 patients with CF-LVAD (aged 58 ± 11 years, 23 males) completed a hemodynamic assessment with either conductance catheters (Group 1, n = 13) inserted into the right ventricle to generate RV pressure‒volume loops or traditional Swan‒Ganz catheters (Group 2, n = 13) during invasive cardiopulmonary exercise testing. Hemodynamics were collected at rest, 2 sub-maximal levels of exercise, and peak effort. Breath-by-breath gas exchange parameters were collected by indirect calorimetry. Group 1 participants also completed an invasive ramp test during supine rest to determine the impact of varying levels of CF-LVAD support on RV function. RESULTS: In Group 1, pump speed modulations minimally influenced RV function. During upright exercise, there were modest increases in RV contractility during sub-maximal exercise, but there were no appreciable increases at peak effort. Ventricular‒arterial coupling was preserved throughout the exercise. In Group 2, there were large increases in pulmonary arterial, left-sided filling, and right-sided filling pressures during sub-maximal and peak exercises. Among all participants, the cardiac output‒oxygen uptake relationship was preserved at 5.8:1. Ventilatory efficiency was severely abnormal at 42.3 ± 11.6. CONCLUSIONS: Patients with CF-LVAD suffer from limited RV contractile reserve; marked elevations in pulmonary, left-sided filling, and right-sided filling pressures during exercise; and severe ventilatory inefficiency. These findings explain mechanisms for persistent reductions in functional capacity in this patient population.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Tran T, Muralidhar A, Hunter K, et al. Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices. J Heart Lung Transplant. 2020. PMID: 33281029. doi:10.1016/j.healun.2020.11.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。