文献速递瓣膜外科

indexed effective orifice area 分类不适用于人工瓣膜-患者不匹配的分级

Why the categorization of indexed effective orifice area is not justified for the classification of prosthesis-patient mismatch.
PubMed 文献 · J Thorac Cardiovasc Surg · 2020-11-12

本研究基于5项试验共2171例接受外科支架生物瓣主动脉瓣置换的患者,分析术后1年超声心动图,探讨 indexed effective orifice area(EOAi)与平均主动脉跨瓣压差的关系。结论认为以EOAi阈值分类PPM缺乏依据,不支持按肥胖调整定义。

要点

  • EOAi与平均压差的指数关系较原始阈值来源研究更平缓,log尺度斜率-0.83 vs -2.5。
  • ASE、VARC-2、EACVI的PPM定义反映压差≥20 mm Hg的准确性分别为49%、57%、57%。

核心结论

  • 以EOAi阈值分类PPM被EOAi与平均压差之间较弱的指数关系所削弱。
  • 近期在PPM定义中按肥胖调整的做法不被本研究数据支持。

研究设计与样本

  • 研究纳入5项试验(CoreValve US High-Risk、SURTAVI、Evolut Low Risk、PERIGON Pivotal、PERIGON Japan)中2171例接受外科支架生物瓣主动脉瓣置换的患者。
  • 分析术后1年随访超声心动图,评估EOAi与平均主动脉压差的关系及其与肥胖等特征的交互作用。
  • 比较不同PPM定义反映平均压差升高(≥20 mm Hg)的准确性。

主要发现

  • EOAi增加时平均压差的指数衰减较原始阈值来源研究更平缓,log尺度斜率-0.83 vs -2.5。
  • ASE、VARC-2、EACVI的PPM定义反映平均压差≥20 mm Hg的准确性分别为49%、57%、57%。

关键数值与推荐

  • 平均压差升高定义为≥20 mm Hg。
  • ASE、VARC-2、EACVI的PPM定义准确性分别为49%、57%、57%。

临床怎么用

  • 不应仅凭EOAi阈值分类PPM,需结合平均压差等血流动力学指标综合评估。
  • 在PPM定义中按肥胖调整缺乏数据支持,临床不宜常规采用。

局限性

  • 分析基于5项试验中接受外科支架生物瓣的患者,结论外推需谨慎。
  • 仅使用术后1年超声心动图评估,未反映更长期变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Although the impact of prosthesis-patient mismatch (PPM) on survival has been widely studied, there has been little debate about whether the current definition of PPM truly reflects hemodynamic obstruction. This study aimed to validate the categorization of indexed effective orifice area (EOAi) for the classification of PPM. METHODS: In total, 2171 patients who underwent aortic valve replacement with a surgical stented bioprosthesis in 5 trials (CoreValve US High-Risk, SURTAVI [Surgical Replacement and Transcatheter Aortic Valve Implantation Trial], Evolut Low Risk, PERIGON [PERIcardial SurGical AOrtic Valve ReplacemeNt] Pivotal Trial for the Avalus valve, and PERIGON Japan) were used for this analysis. The echocardiographic images at the 1-year follow-up visit were evaluated to explore the association between EOAi and mean aortic gradient and its interaction with other patient characteristics, including obesity. In addition, different criteria of PPM were compared with reflect elevated mean aortic gradients (≥20 mm Hg). RESULTS: A relatively smaller exponential decay in mean aortic gradient was found for increasing EOAi, as the slope on the log scale was -0.83 versus -2.5 in the publication from which the current cut-offs for PPM originate. The accuracy of the American Society of Echocardiography, Valve Academic Research Consortium-2, and European Association of Cardiovascular Imaging definitions of PPM to reflect elevated mean aortic gradients was 49%, 57%, and 57%, respectively. The relation between EOAi and mean aortic gradient was not significantly different between obese and non-obese patients (P = .20). CONCLUSIONS: The use of EOAi thresholds to classify patients with PPM is undermined by a less-pronounced exponential relationship between EOAi and mean aortic gradient than previously demonstrated. Moreover, recent adjustment for obesity in the definition of PPM is not supported by these data.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Vriesendorp MD, Deeb GM, Reardon MJ, et al. Why the categorization of indexed effective orifice area is not justified for the classification of prosthesis-patient mismatch. J Thorac Cardiovasc Surg. 2020. PMID: 33339597. doi:10.1016/j.jtcvs.2020.10.123

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。