文献速递瓣膜外科主动脉外科

二叶式与三叶式主动脉瓣修复术的比较

Comparison of bicuspid and tricuspid aortic valve repair.
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01

本研究比较了三叶式主动脉瓣(TAV)与二叶式主动脉瓣(BAV)修复术后的结局。2010年1月至2020年4月共行368例择期主动脉瓣修复术,其中TAV组223例(60.6%)。BAV修复耐久性与TAV相当,BAV并非再手术率更高的预测因素,且BAV修复生存率与预期生存相当;瓣叶穿孔、使用心包补片及主动脉瓣环直径>27.5 mm对远期结局有不利影响。

要点

  • BAV修复耐久性与TAV相当,5年免再手术率分别为93±4%与96±3%(P=0.28)。
  • BAV组5年估计生存率97±3%,显著高于TAV组的80±6%(P<0.001)。
  • 瓣叶穿孔、使用心包补片及瓣环直径>27.5 mm是再手术的预测因素。

核心结论

  • BAV修复耐久性与TAV修复相当,BAV并非再手术率更高的预测因素。
  • BAV修复的生存率与预期生存相当。
  • 瓣叶穿孔、主动脉瓣环直径>27.5 mm及使用心包补片对主动脉瓣修复远期结局有不利影响。

研究设计与样本

  • 回顾性比较研究,纳入2010年1月至2020年4月共368例择期主动脉瓣修复术,其中TAV组223例(60.6%)。
  • 评估死亡率、免再手术率及主动脉瓣反流复发率,并与预期生存比较,识别再手术危险因素。

主要发现

  • 围术期死亡率BAV组0.7%,TAV组3.6%(P=0.079)。
  • 5年估计生存率BAV组97±3%,TAV组80±6%(P<0.001)。
  • 5年免再手术率TAV组96±3%,BAV组93±4%(P=0.28)。
  • 主动脉瓣反流≥2级在BAV组占9.9%,TAV组占11%(P=0.66)。
  • 再手术预测因素:瓣叶穿孔HR 15.86(4.44-56.61),P<0.001;使用心包补片HR 8.58(1.96-37.53),P=0.004;主动脉瓣环直径>27.5 mm HR 3.07(0.99-9.58),P=0.053。

临床怎么用

  • BAV修复可作为与TAV修复同样持久的治疗选择,BAV本身不应视为再手术高危因素。
  • 围术期应关注瓣叶穿孔、心包补片使用及瓣环直径>27.5 mm等影响远期结局的因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The aim of this study was to compare the outcomes of tricuspid aortic valve (TAV) and bicuspid aortic valve (BAV) repair. METHODS: We assessed mortality, freedom from reoperation and the rate of aortic valve regurgitation recurrence. Mortality in both groups was compared with expected survival, and risk factors for reoperation were identified. RESULTS: From January 2010 to April 2020, a total of 368 elective aortic valve repair procedures were performed, including 223 (60.6%) in patients with TAV. The perioperative mortality was 0.7% in the BAV group and 3.6% in the TAV group (P = 0.079). Estimated survival at 5 years in the BAV versus TAV group was 97 ± 3% vs 80 ± 6%, respectively (P < 0.001). Freedom from reoperation at 5 years in the TAV versus BAV group was 96 ± 3% vs 93 ± 4%, respectively (P = 0.28). Grade 2 or more aortic valve regurgitation was noted in 9.9% of BAV patients and 11% of TAV patients (P = 0.66). Reoperation was predicted by cusp perforation [hazard ratio 15.86 (4.44-56.61); P < 0.001], the use of pericardial patch [hazard ratio 8.58 (1.96-37.53); P = 0.004] and aortic valve annulus diameter >27.5 mm [hazard ratio 3.07 (0.99-9.58); P = 0.053]. CONCLUSIONS: BAV repair is as durable as TAV repair. BAV is not a predictor of a higher rate of reoperations. BAV repair yields survival comparable to expected. Cusp perforation, aortic valve annulus diameter >27.5 mm and the use of pericardial patch adversely impact long-term outcome of aortic valve repair.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Gocoł R, Bis J, Malinowski M, et al. Comparison of bicuspid and tricuspid aortic valve repair. Eur J Cardiothorac Surg. 2021. PMID: 33367683. doi:10.1093/ejcts/ezaa462

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。