辅助性血管内球囊断裂开窗术治疗慢性主动脉夹层
本研究评估了在胸主动脉腔内修复术(TEVAR)中辅助使用球囊断裂开窗术(BFF)治疗因负性重构导致动脉瘤的慢性主动脉夹层患者的效果。结论认为BFF在短期随访中有益,可能促进正性主动脉重构,值得进一步研究。
要点
- TEVAR联合BFF治疗慢性主动脉夹层短中期安全可行,1年生存率91%。
- 73.5%患者实现治疗段假腔完全血栓形成,真腔面积持续扩大。
- 13例出现正性重构,最大主动脉直径平均缩小11 mm。
核心结论
- BFF是TEVAR治疗慢性主动脉夹层的有效辅助手段,短期随访中可能促进正性主动脉重构,值得进一步研究。
研究设计与样本
- 单中心回顾性研究,纳入2013年6月至2016年1月49例因负性重构导致动脉瘤的慢性主动脉夹层患者,均接受TEVAR联合BFF。
主要发现
- 术中所有患者均实现腔内支架移植物扩张。
- 住院死亡1例,死于计划BFF前已存在的慢加急性夹层相关内脏灌注不良。
- 无截瘫发生,3例卒中,3例急性肾衰竭。
- 1年生存率91%。
- 16例因假腔未完全隔绝需晚期再干预,1年免于再干预率75%。
临床怎么用
- 对于慢性主动脉夹层负性重构患者,TEVAR术中可考虑辅助BFF以促进假腔血栓形成和主动脉正性重构。
- 术后需定期CT随访评估假腔血栓形成、主动脉直径和真腔变化,以及时发现需要再干预的患者。
局限性
- 样本量较小(49例),随访时间较短(短期随访)。
- 单中心回顾性设计,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Positive remodeling after thoracic endovascular aortic repair (TEVAR) for chronic thoracic aortic dissection is variable due to incomplete distal seal and retrograde false lumen perfusion. We assessed the outcomes of adjunctive balloon fracture fenestration (BFF) during TEVAR in patients with chronic aortic dissection complicated by negative remodeling. METHODS: From June 2013 to January 2016, 49 patients with chronic aortic dissection complicated by aneurysm due to negative remodeling underwent TEVAR with BFF. Contrast-enhanced computed tomography was performed before discharge, at 3 to 6 months, and annually. RESULTS: Intraoperatively, endovascular stent graft expansion was achieved in all patients. There was 1 hospital death due to visceral malperfusion related to acute-on-chronic dissection noted before planned BFF. There were no occurrences of paraplegia, 3 patients had stroke, and 3 had acute renal failure. Survival at 1 year was 91%. Late reintervention for incomplete false lumen exclusion was required in 16 patients and freedom from reintervention was 75% at 1 year. Thirty-six patients (73.5%) had complete false lumen thrombosis through the treated segment. True lumen area increased following TEVAR with BFF and continued to incrementally expand with subsequent aortic remodeling at 1-year follow-up. Thirteen patients had positive remodeling, defined as thrombosis of false lumen, ≥10% decrease in aortic dimension, and ≥10% increase in true lumen diameter. Patients with positive remodeling had an average decrease of 11 mm in maximal aortic diameter at final follow-up. CONCLUSIONS: BFF of chronic dissection membrane is a beneficial adjunct to TEVAR during short-term follow-up and may promote positive aortic remodeling and is worthy of further study.
引用
- Levack MM, Kindzelski BA, Miletic KG, et al. Adjunctive endovascular balloon fracture fenestration for chronic aortic dissection. J Thorac Cardiovasc Surg. 2020. PMID: 33220972. doi:10.1016/j.jtcvs.2020.09.106
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。