三尖瓣缘对缘修复的长期临床与血流动力学结局
该单中心回顾性研究纳入237例接受三尖瓣缘对缘修复的患者,评估其长期临床与血流动力学结局。术后92.8%患者三尖瓣反流轻微或更轻,10年全因死亡免除率80.6%,中重度三尖瓣反流免除率84.9%,三尖瓣再手术免除率99.1%。结论认为该技术安全有效。
要点
- 三尖瓣缘对缘修复术后10年全因死亡免除率为80.6%。
- 10年中重度三尖瓣反流免除率为84.9%,再手术免除率99.1%。
- 术后92.8%患者三尖瓣反流为轻度或更轻。
核心结论
- 三尖瓣缘对缘修复显示出可接受的长期临床与血流动力学结果,是三尖瓣手术中有效且安全的选择。
研究设计与样本
- 回顾性单中心研究,纳入2001年1月至2019年3月接受三尖瓣缘对缘修复的237例患者,平均年龄58.4±13.9岁。
主要发现
- 术后超声显示220例(92.8%)三尖瓣反流为轻度或更轻。
- 早期死亡率(<30天)为3.8%(9例),因出血再手术6.8%(16例),低心排综合征6.4%(15例)。
- 5年和10年全因死亡免除率分别为87.2%和80.6%。
- 5年和10年中重度三尖瓣反流免除率分别为97.1%和84.9%。
- 5年和10年显著三尖瓣狭窄(跨三尖瓣压差≥5 mm Hg)免除率分别为96.4%和88.4%。
关键数值与推荐
- 三尖瓣成形术175例(73.8%),其中环成形91例(38.4%),缝线成形84例(35.4%)。
临床怎么用
- 对于适合的三尖瓣反流患者,三尖瓣缘对缘修复可作为三尖瓣手术中安全有效的选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The edge-to-edge technique (Alfieri stitch) has been widely adopted in mitral valve but not tricuspid valve (TV) repair. We evaluated long-term clinical and hemodynamic outcomes of tricuspid edge-to-edge repair. METHODS: We retrospectively reviewed 237 patients (mean age, 58.4 ± 13.9 years) who had undergone tricuspid edge-to-edge repair from January 2001 to March 2019 in our institution. Tricuspid annuloplasty was performed in 175 patients (73.8%) using ring (91 [38.4%]) or suture (84 [35.4%]) annuloplasty. Concomitant procedures were mitral valve replacement (133 [56.1%]), mitral valve repair (52 [21.9%]), aortic valve replacement (41 [17.3%]), and maze operation (138 [58.2%]). RESULTS: Postoperative echocardiography revealed mild or less tricuspid regurgitation (TR) in 220 patients (92.8%). Early mortality (<30 days) occurred in 9 patients (3.8%), reoperation for bleeding in 16 (6.8%), and low cardiac output syndrome in 15 (6.4%). Freedom from all-cause mortality was 87.2% at 5 years and 80.6% at 10 years. Freedom from moderate or severe TR was 97.1% at 5 years and 84.9% at 10 years. Transtricuspid pressure gradient was 3.8 ± 4.2 mm Hg at discharge and 3.2 ± 5.6 mm Hg at the last follow-up (P = .60). Freedom from significant tricuspid stenosis (transtricuspid pressure gradient ≥5 mm Hg) was 96.4% and 88.4% at 5 and 10 years, respectively. There was 1 early TV reoperation for severe TR on postoperative day 3 (0.4%). Freedom from TV reoperation was 99.1% at 10 years. CONCLUSIONS: Tricuspid edge-to-edge repair showed acceptable long-term clinical and hemodynamic results and is an effective and safe option in TV surgery.
引用
- Lee H, Kim J, Oh SS, et al. Long-term Clinical and Hemodynamic Outcomes of Edge-to-Edge Repair for Tricuspid Regurgitation. Ann Thorac Surg. 2020. PMID: 33157062. doi:10.1016/j.athoracsur.2020.09.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。