骨骼化左乳内动脉减少CABG术后出血:一项随机对照试验
这项随机单盲平行对照试验纳入62例择期CABG患者,比较骨骼化与带蒂左乳内动脉获取对术后出血的影响。骨骼化LIMA可减少术后出血和输血需求。
要点
- 骨骼化LIMA较带蒂获取显著降低12小时引流液28%
- 骨骼化降低术后12小时高引流风险(OR=0.04)
核心结论
- 骨骼化LIMA获取较带蒂获取降低CABG术后纵隔引流量,并减少新鲜冰冻血浆输注。
- 骨骼化LIMA与更高的BMI均降低12小时引流量处于最高四分位(≥550 mL)的风险。
- 两组间凝血指标无差异,但骨骼化组术后肌酸激酶水平更低。
研究设计与样本
- 随机、单盲、平行分组、等分配的对照试验,共62例择期初次CABG患者,骨骼化组与带蒂组各31例,全部纳入分析。
- 术前评估凝血各方面,患者对LIMA获取技术盲法,监测12小时累积引流量(主要结局)及心肌坏死标志物。
临床怎么用
- 在择期CABG中可考虑采用骨骼化LIMA获取以降低术后出血和输血需求。
- 骨骼化LIMA可能有助于减少术后心肌损伤标志物释放,但需结合临床判断。
局限性
- 单中心、样本量较小(62例),随访仅至术后12小时。
- 患者对LIMA获取技术盲法,但外科医生未盲。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The objective of this study was to compare the impact of skeletonized versus pedicled left internal mammary artery (LIMA) harvesting on bleeding after coronary artery bypass grafting (CABG). METHODS: In a randomized, single-blinded trial with a parallel group design and equal allocation, we randomly assigned 62 patients undergoing primary elective CABG in a tertiary cardiac center to skeletonized or pedicled LIMA dissection. Before surgery, all aspects of coagulation were assessed. Patients were blinded to LIMA dissection technique and monitored for cumulative drainage at 12 hours (primary outcome) as well as myocardial necrosis markers. RESULTS: With recruitment complete, there were 31 patients in each group; all patients were analyzed. Median postoperative drainage was 395 mL at 12 hours in all patients; it was lower by 28% at 12 hours (P = .02) in patients with skeletonized LIMA (Cohen's d, 0.6; 95% confidence interval (CI), 0.09-1.11). Patients with a LIMA pedicle received more fresh-frozen plasma transfusions than did the skeletonized LIMA group (Median 3; interquartile range 3-5 versus median 3; interquartile range 3-3; P = .03). Study arms did not differ in blood coagulation. Left internal mammary artery skeletonization (odds ratio = 0.04; 95% CI, 0.003-0.44; P = .009) and higher body mass index (odds ratio = 0.63; 95% CI, 0.45-0.89; P = .008) decreased the odds of being in the top drainage quartile at 12 hours (≥550 mL). Creatine kinase was lower in skeletonized LIMA directly after surgery (median 218 U/L; interquartile range 175-310 U/L versus median 424 U/L; interquartile range 256-510 U/L; P < .001), at 6 hours (median 324 U/L; interquartile range 239-424 U/L versus median 529 U/L; interquartile range 374-707 U/L; P < .001), and 12 hours after surgery (median 351 U/L; interquartile range 277-552 U/L versus median 695 U/L; interquartile range 509-1067 U/L; P < .001). CONCLUSIONS: Left internal mammary artery skeletonization results in lower mediastinal drainage after CABG than pedicled LIMA harvesting.
引用
- Mazur P, Litwinowicz R, Tchantchaleishvili V, et al. Left Internal Mammary Artery Skeletonization Reduces Bleeding-A Randomized Controlled Trial. Ann Thorac Surg. 2020. PMID: 33171172. doi:10.1016/j.athoracsur.2020.10.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。