急性A型主动脉夹层补片新内膜技术中期结果:147例分析
该研究回顾了147例接受补片新内膜技术保留主动脉瓣的主动脉根部修复术的急性A型主动脉夹层患者,围术期死亡率为5.4%,中期随访显示主动脉瓣功能稳定且主动脉根部无扩张。
要点
- 补片新内膜技术保留主动脉瓣修复急性A型主动脉夹层,围术期死亡率5.4%。
- 中期随访7年,82%患者无主动脉瓣反流,无因主动脉根部再手术。
- 窦管交界和窦部直径在随访期间保持稳定,无扩张。
核心结论
- 补片新内膜技术行保留主动脉瓣的主动脉根部修复术与中期主动脉瓣功能稳定及主动脉根部无扩张相关。
研究设计与样本
- 回顾性分析2009年1月至2012年12月本中心147例接受补片新内膜技术保留主动脉瓣主动脉根部修复术的A型主动脉夹层患者,通过超声心动图和主动脉CTA评估中期结果。
主要发现
- 147例患者中,32例(21.8%)行近端弓部修复,115例(78.2%)行近端弓部修复联合三分支支架植入。
- 围术期死亡率为5.4%。
- 术前94例(63.9%)存在主动脉瓣反流;131例(89.1%)出手术室时无主动脉瓣反流,其余16例(10.9%)有微量或小于1+反流。
- 128例(87.1%)完成7年随访,平均随访时间5.7±1.2年;82%(105例)患者无主动脉瓣反流,15.6%(20例)有0.5+微量或小于1+反流;无因主动脉根部再手术。
- 窦管交界和窦部直径分别降至正常范围(28.3±4.2 mm和30.5±3.6 mm),并在7年随访期间保持稳定(28.9±5.6 mm,P=.300;30.8±4.2 mm,P=.540)。
临床怎么用
- 对于急性A型主动脉夹层,补片新内膜技术可作为一种保留主动脉瓣的根部修复选择,中期随访显示瓣膜功能稳定且根部无扩张。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The patch neointima technique is a modified valve-sparing aortic root repair surgery for acute type A aortic dissection and the short-term outcomes are satisfactory. The midterm outcomes have not been reported. METHODS: From January 2009 to December 2012, 147 patients underwent valve-sparing aortic root repair with the patch neointima technique for type A aortic dissection in our center. The midterm outcomes of the patients were evaluated by echocardiography and aortic computed tomography angiography. RESULTS: Of 147 patients, 32 patients (21.8%) underwent proximal arch repair, and 115 patients (78.2%) underwent proximal arch repair combined with triple-branched stent graft implantation. The perioperative mortality was 5.4%. Preoperative aortic insufficiency (AI) was observed in 94 patients (63.9%); 131 patients (89.1%) left the operating room with 0 AI; the remaining 16 patients (10.9%) had trace or less than 1+ AI. A total of 128 patients (87.1%) completed 7-year follow-up. The mean follow-up time was 5.7 ± 1.2 years. As many as 82% of patients (105) were 0 AI and 15.6% of patients (20) were 0.5+ trace or less than 1+ AI. No reoperation was performed for the aortic root. The diameters of sinotubular junction and sinus were reduced to the normal range (28.3 ± 4.2 mm and 30.5 ± 3.6 mm, respectively) and remained stable (28.9 ± 5.6 mm, P = .300, and 30.8 ± 4.2 mm, P = .540, respectively) during 7 years of follow-up. CONCLUSIONS: Valve-sparing aortic root repair with patch neointima technique was associated with stable function of the aortic valves and no expansion of the aortic root in the midterm.
引用
- Dai XF, Fang GH, Yan LL, et al. Patch Neointima Technique in Acute Type A Aortic Dissection: Midterm Results of 147 Cases. Ann Thorac Surg. 2020. PMID: 33098877. doi:10.1016/j.athoracsur.2020.08.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。