缩环成形与局部缝线成形修复功能性三尖瓣反流的血流动力学结局
本研究在离体功能性三尖瓣反流(FTR)猪心模型中,比较了26 mm Edwards MC3瓣环成形环(TVA)与Hetzer局部缝线成形的血流动力学结局。两种方法分别减少反流50%和56%,但均未消除反流,且瓣叶牵拉与活动度受限持续存在。
要点
- TVA与Hetzer成形均不能完全消除FTR,分别减少50%和56%。
- Hetzer可显著减小前间隔牵拉面积,TVA无此效果。
- 两种技术均显著减小后间隔牵拉面积,但瓣叶活动受限持续。
核心结论
- 瓣环成形环或局部缝线成形均可减少FTR但不能消除,瓣环方法未解除瓣叶牵拉且活动度受限持续。
研究设计与样本
- 离体FTR模型研究,通过急性后负荷升高诱导右室扩张制作猪心FTR模型,共10颗猪心。
主要发现
- 基线无FTR,后负荷升高后反流量为17.7 ± 9.2 mL(反流分数26.38 ± 17.47%,P < .0001)。
- TVA减少反流50%,Hetzer减少56%,两者均残留FTR。
- 前间隔牵拉面积修复前279.0 ± 158.9 mm2,Hetzer后降至147.2 ± 134.8 mm2(P = .0195),TVA无显著变化。
- 后间隔牵拉面积修复前425.1 ± 169.2 mm2,TVA后200.3 ± 102.9 mm2(P = .0012),Hetzer后237.6 ± 127.6 mm2(P = .0270)。
关键数值与推荐
- TVA使用26-mm Edwards MC3环,Hetzer使用带垫片缝线环缩前后瓣环与隔瓣环。
临床怎么用
- 瓣环成形可能不足以完全纠正FTR,需考虑瓣下修复或谨慎评估瓣膜置换的必要性。
局限性
- 离体猪心模型,样本量10颗,结果外推至临床需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Surgical annuloplasty for functional tricuspid regurgitation (FTR) is on the rise and can be performed in several ways with varied outcomes. In this study, we sought to compare the hemodynamic outcomes of tricuspid annuloplasty performed with a commercially available annuloplasty ring (tricuspid valve annuloplasty [TVA]) compared with focal suture annuloplasty (Hetzer) in an experimental FTR model. METHODS: An ex vivo FTR model was developed by inducing right ventricular dilatation by acute afterload elevation, causing severe tricuspid valve tethering and annular dilatation, leading to regurgitation. Ten porcine hearts in which FTR was induced underwent TVA with a 26-mm Edwards MC3 ring and Hetzer annuloplasty with a pledgeted suture cinching the anteroposterior and septal annulus. FTR was measured before after each repair, and tenting geometry, valve kinematics, and subvalvular geometry were measured with echocardiography. RESULTS: At baseline, none of the hearts had FTR, but upon afterload elevation an FTR volume of 17.7 ± 9.2 mL (26.38 ± 17.47% regurgitant fraction) was measured (P < .0001). TVA reduced regurgitation by 50% and Hetzer annuloplasty by 56% , respectively, but both left persistent FTR. Anteroseptal tenting area was 279.0 ± 158.9 mm2 before repair and decreased significantly to 147.2 ± 134.8 mm2 (P = .0195) with Hetzer but not with TVA. Posteroseptal tenting area was 425.1 ± 169.2 mm2 before repair and was significantly reduced by both techniques (TVA: 200.3 ± 102.9 mm2 [P = .0012]; Hetzer: 237.6 ± 127.6 mm2 [P = .0270]). CONCLUSIONS: Tricuspid annuloplasty with a ring or a focal suture can reduce FTR but not eliminate it. Annular approaches did not relieve tricuspid valve tethering and reduced leaflet mobility persisted. Either subannular repairs or judicious use of valve replacement may be necessary.
引用
- Amedi A, Onohara D, Xu D, et al. Hemodynamic outcomes after undersizing ring annuloplasty and focal suture annuloplasty for surgical repair of functional tricuspid regurgitation. J Thorac Cardiovasc Surg. 2020. PMID: 33041065. doi:10.1016/j.jtcvs.2020.08.085
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。