高流量CO2辅助机械瓣血栓外科治疗
Surgical treatment of prosthetic mechanical valve thrombosis with the aid of high-flow CO2.
PubMed 文献 · Eur J Cardiothorac Surg · 2021-01-01
本文介绍一例机械瓣血栓患者,手术涉及再次瓣膜置换及血栓层清除。双叶机械瓣铰链及近铰链区为血流停滞区,易形成血栓且手术器械难以到达。本例采用高流量CO2辅助清除机械瓣周围停滞区的微血栓。
要点
- 机械瓣铰链区为血流停滞区,易形成血栓且器械难以到达
- 高流量CO2可辅助清除停滞区微血栓
- 手术方式为再次瓣膜置换加血栓清除
核心结论
- 高流量CO2可辅助清除机械瓣停滞区的微血栓。
研究设计与样本
- 个案报道,介绍一例机械瓣血栓患者的手术处理。
主要发现
- 双叶机械瓣铰链及近铰链区为血流停滞区,易形成血栓且手术器械不易到达。
- 本例使用高流量CO2辅助清除了机械瓣周围停滞区的微血栓。
临床怎么用
- 机械瓣血栓再次手术时,可考虑用高流量CO2辅助清除铰链区微血栓。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The surgical treatment of prosthetic mechanical valve thrombosis involves redo valve replacement and removal of the thrombi layers. The hinges and near-hinge areas of the bi-leaflet mechanical valve are a 'stagnation area' where blood flow is typically unsteady and can give rise to thrombi; however, these zones are not easily accessed with surgical instruments. Here, we present a case in which high-flow CO2 was used to facilitate the removal of microthrombi in the stagnation area around a prosthetic mechanical valve.
来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。
引用
- Moscarelli M, Nasso G, Vite G, et al. Surgical treatment of prosthetic mechanical valve thrombosis with the aid of high-flow CO2. Eur J Cardiothorac Surg. 2021. PMID: 33020841. doi:10.1093/ejcts/ezaa349
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。