文献速递心外重症与机械循环支持

HeartWare HVAD双心室辅助装置的国际经验

International experience using a durable, centrifugal-flow ventricular assist device for biventricular support.
PubMed 文献 · J Heart Lung Transplant · 2020-08-20

该回顾性研究纳入2009至2017年12个中心的93例HVAD双心室辅助装置患者,1年和2年Kaplan-Meier生存率分别为56%和47%。生存与RVAD植入位置(右心室或右心房)及是否分期植入无关,最常见不良事件为出血(35.5%)、感染(25.8%)和呼吸衰竭(20.4%)。

要点

  • HVAD双心室辅助1年和2年生存率分别为56%和47%。
  • RVAD植入位置(右心室或右心房)不影响生存和不良事件。
  • 最常见不良事件为出血、感染和呼吸衰竭。

核心结论

  • HVAD双心室辅助患者1年和2年生存率分别为56%和47%。
  • 原期或分期植入HVAD双心室辅助的1年和2年生存相似。
  • RVAD植入位置(右心室或右心房)导致相似的不良事件谱。

研究设计与样本

  • 回顾性研究,纳入2009至2017年12个中心植入HVAD双心室辅助装置的患者93例。

主要发现

  • 93例HVAD双心室辅助患者1年和2年Kaplan-Meier生存率分别为56%和47%。
  • 生存与HVAD RVAD植入位置(右心室或右心房)无关。
  • 生存与左VAD和RVAD植入之间是否有间隔无关。
  • 最常见不良事件为出血(35.5%)、感染(25.8%)和呼吸衰竭(20.4%)。

临床怎么用

  • HVAD可用于双心室辅助,原期或分期植入及右心室或右心房植入均可考虑。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Heart transplantation is limited by the scarcity of suitable donors. Patients with advanced biventricular failure may require biventricular support to provide optimal cardiac output and end-organ perfusion. We highlight the outcomes of using the HeartWare HVAD System (HVAD) in a biventricular configuration. METHODS: This retrospective study included patients implanted with HVAD as a biventricular assist device (BiVAD) between 2009 and 2017 at 12 participating centers. When used as a right ventricular assist device (VAD) (RVAD), the HVAD can be attached to the right ventricle (RV) or the right atrium (RA). Kaplan-Meier survival estimates were calculated comparing the 2 RVAD implant locations. Comparisons were also made between the timing of RVAD implantation (primary vs staged) on adverse event (AE) profiles and survival. RESULTS: Among the 93 patients who were implanted with a HVAD BiVAD, Kaplan-Meier survivals at 1-year and 2-year were 56% and 47%, respectively. Survival was independent of the location of the HVAD RVAD implant or whether there was an interval between left VAD and RVAD implantation. The most common AEs were bleeding (35.5%), infection (25.8%), and respiratory failure (20.4%). CONCLUSIONS: This study illustrated similar survival in patients receiving a primary or staged HVAD BiVAD implant at 1 year and 2 years. This study also established that the locations of the RVAD implant (RV or RA) result in similar AE profiles.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Marasco S, Simon AR, Tsui S, et al. International experience using a durable, centrifugal-flow ventricular assist device for biventricular support. J Heart Lung Transplant. 2020. PMID: 32917479. doi:10.1016/j.healun.2020.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。