文献速递肺外科

肺灌注扫描与SPECT/CT预测临界肺功能患者术后肺功能的比较

Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

本研究纳入274例FEV1或DLCO低于80%的临界肺功能患者,比较肺灌注扫描(LPS)与SPECT/CT预测术后肺功能的价值。结果显示两种方法在各肺叶摄取率(除右中叶外)一致性尚可,预测术后FEV1和DLCO高度一致且与实测值显著相关,LPS在再手术病例中表现良好。

要点

  • LPS与SPECT/CT预测的ppoFEV1和ppoDLCO高度一致(一致性相关系数分别为0.93和0.92)。
  • 两种方法预测的ppoFEV1和ppoDLCO均与术后实测值显著相关(r=0.77和r=0.62)。
  • 在再手术病例中,LPS与SPECT/CT的摄取率及预测值仍保持高度一致性。

核心结论

  • LPS与SPECT/CT对临界肺功能患者术后肺功能均有较高预测价值,LPS可参考SPECT/CT用于估算ppoFEV1和ppoDLCO。

研究设计与样本

  • 回顾性比较研究,纳入274例同时接受LPS和SPECT/CT且FEV1或DLCO低于80%的患者。

主要发现

  • 各肺叶摄取率除右中叶外一致性尚可(右中叶一致性相关系数0.37,其余0.61-0.71)。
  • ppoFEV1和ppoDLCO在两种方法间高度一致(一致性相关系数0.93和0.92),差异无统计学意义(P=0.42和P=0.31)。
  • 两种方法预测的ppoFEV1与实测FEV1显著相关(r=0.77,P<0.01),ppoDLCO与实测DLCO显著相关(r=0.62,P<0.01)。
  • 再手术病例中,两种方法的摄取率、ppoFEV1和ppoDLCO仍保持高度一致性。

临床怎么用

  • 对于临界肺功能患者,LPS可作为SPECT/CT的替代方法预测术后肺功能,尤其在再手术病例中。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We compared the usefulness of single-photon emission computed tomography/computed tomography (SPECT/CT) and lung perfusion scintigraphy (LPS) for predicting postoperative lung function by comparing patients with borderline lung function. METHODS: A total of 274 patients who underwent simultaneous LPS and SPECT/CT and had a forced expiratory volume in 1 s (FEV1) or diffusing capacity for carbon monoxide (DLCO) under 80% were included. The % uptake by LPS was calculated by the posterior-oblique method. The concordance and difference of the % uptake, predicted postoperative (ppo) FEV1 and ppoDLCO as determined by 2 methods were evaluated. The association between ppo values and actual postoperative FEV1 and DLCO was examined. Subgroup analysis was conducted in redo-operation cases. RESULTS: The % uptake of each lobe, except the right middle lobe, showed fair concordance (concordance correlation coefficients for right upper, middle, lower, left upper and lower lobe = 0.61, 0.37, 0.71, 0.66 and 0.69, respectively). ppoFEV1 and ppoDLCO also revealed high concordance between both methods (concordance correlation coefficient = 0.93 for ppoFEV1 and concordance correlation coefficient = 0.92 for ppoDLCO) without a significant difference (P = 0.42 for ppoFEV1; P = 0.31 for ppoDLCO). Both ppoFEV1 and ppoDLCO showed a significantly high correlation with the actual FEV1 (r = 0.77, P < 0.01 for LPS, r = 0.77, P < 0.01 for SPECT/CT) and DLCO (r = 0.62, P < 0.01 for LPS, r = 0.62, P < 0.01 for SPECT/CT). High concordance of % uptake, ppoFEV1 and ppoDLCO was present in redo-operation patients. CONCLUSIONS: Both LPS and SPECT/CT showed high predictability for actual postoperative lung function, and LPS showed good performance to estimate ppoFEV1 and ppoDLCO with reference to SPECT/CT, even in redo-operation cases.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Na KJ, Park S, Lee HJ, et al. Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function. Eur J Cardiothorac Surg. 2020. PMID: 32879936. doi:10.1093/ejcts/ezaa211

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。