经导管主动脉瓣置换术中辐射暴露:动脉入路与瓣膜类型的影响
前瞻性研究纳入140例TAVR患者,经股动脉102例、经颈动脉38例,自膨胀瓣膜38例、球囊扩张瓣膜102例。经颈动脉入路术者辐射剂量增加4倍,自膨胀瓣膜与更长X线时间和2倍术者剂量相关,但校正混杂后瓣膜类型不再显著。
要点
- 经颈动脉TAVR术者辐射暴露是经股动脉的4倍,校正后仍增加174.8%。
- 自膨胀瓣膜与更长X线时间相关,但校正混杂后对术者剂量无显著影响。
- 患者辐射剂量不受动脉入路或瓣膜类型显著影响。
核心结论
- 经颈动脉入路和自膨胀瓣膜分别与术者辐射暴露增加4倍和2倍相关,但瓣膜类型的影响在校正后不再显著。
研究设计与样本
- 前瞻性研究纳入140例连续TAVR患者,经股动脉102例、经颈动脉38例,自膨胀瓣膜38例、球囊扩张瓣膜102例,来自2个中心。
主要发现
- 经颈动脉TAVR术者辐射暴露增加4倍(P < .001)。
- 自膨胀瓣膜与更长X线时间(P = .015)和2倍术者辐射剂量(P = .018)相关。
- 患者辐射剂量不受动脉入路(P = .055)或瓣膜类型(P = .095)显著影响。
- 校正混杂后经颈动脉入路仍与术者剂量增加174.8%(95%CI 80.6-318.3,P < .001)相关,自膨胀瓣膜不再影响术者剂量(P = .630)。
临床怎么用
- 经颈动脉入路TAVR时应加强术者辐射防护。
- 选择自膨胀瓣膜时需关注X线时间延长对术者辐射暴露的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The impact of novel alternative access and valve type on radiation exposure during transcatheter aortic valve replacement (TAVR) has not yet been evaluated. This study sought to determine the impact of a transarterial approach and prosthesis type on physician and patient exposure to radiation during TAVR. METHODS: This was a prospective study including 140 consecutive patients undergoing TAVR by transfemoral (n = 102) or transcarotid (TC) (n = 38) access at 2 centers. Implanted valves were the self-expanding Evolut R/PRO system (Medtronic, Minneapolis, MN; n = 38) and the balloon-expandable SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA; n = 102). The primary endpoint was first operator radiation exposure. The secondary endpoint was patient radiation exposure. RESULTS: First operator radiation exposure was 4-fold greater during TC TAVR (P < .001). The use of a self-expanding valve was associated with a longer x-ray time (P = .015) and a 2-fold greater first operator radiation dose (P = .018). Patient radiation dose was not significantly affected by arterial approach (P = .055) or valve type (P = .095). After adjustment for potential confounders, the TC approach remained associated with a 174.8% (95% confidence interval, 80.6-318.3, P < .001) increase in first operator radiation dose, whereas the use of a self-expanding valve no longer influenced the first operator dose (P = .630). CONCLUSIONS: TC access and the use of a self-expanding valve were associated with a 4- and 2-fold greater first operator radiation exposure during TAVR procedures, respectively. Unlike the arterial approach, the effect of bioprosthesis type on radiation exposure was mainly related to x-ray time and was no longer significant after adjustment.
引用
- Faroux L, Villecourt A, Guimaraes L, et al. Radiation Exposure During Transcatheter Aortic Valve Replacement: Impact of Arterial Approach and Prosthesis Type. Ann Thorac Surg. 2020. PMID: 32950489. doi:10.1016/j.athoracsur.2020.06.114
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。