文献速递先天性心脏病外科

大口径膨体聚四氟乙烯带瓣管道伴膨出窦的长期结果

Long-term results of large-calibre expanded polytetrafluoroethylene-valved conduits with bulging sinuses.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

该多中心回顾性研究纳入日本34家机构2002至2015年间使用直径≥18 mm自制ePTFE带瓣管道行右心室流出道重建的502例患者,旨在排除体格生长影响后评估其远期耐久性。10年总体生存率96.6%,免于管道取出率89.0%,远期随访肺动脉瓣反流和管道狭窄多为轻度及以下。

要点

  • 大口径ePTFE带瓣管道10年免于取出率89.0%,远期耐久性满意
  • 10年总体生存率96.6%,早期死亡1.4%且与管道失效无关
  • 远期肺动脉瓣反流96%、管道狭窄88%为轻度及以下

核心结论

  • 仅分析大口径ePTFE带瓣管道时,其扇形瓣膜与膨出窦设计显示出满意的长期结局,可作为右心室流出道重建的优选方案之一。

主要发现

  • 早期死亡率为1.4%,与管道失效无关;总体生存率5年98.2%、10年96.6%。
  • 免于管道取出率5年99.5%、10年89.0%;3例(0.13/100患者年)发生管道感染性心内膜炎,仅1例需取出管道。
  • 最近一次随访时,480例(96%)肺动脉瓣反流为轻度及以下,436例(88%)管道狭窄为轻度及以下。

临床怎么用

  • 对于需行右心室流出道重建且体型可容纳大口径管道的患者,大口径ePTFE带瓣管道可作为同种移植物和牛颈静脉之外的长期选择。

局限性

  • 本研究为回顾性设计,仅纳入直径≥18 mm的大口径管道以排除体格生长影响,结果不能直接外推至小口径管道或生长中的儿童群体。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In Japan, homograft and bovine jugular vein are available in very limited institutions for the reconstruction of the right ventricular outflow tract, and handmade expanded polytetrafluoroethylene (ePTFE)-valved conduits have been widely used instead. This study aimed to clarify the long-term outcomes and the durability of the ePTFE-valved conduits purely by narrowing down to those with large sizes to eliminate the influence of the body growth. METHODS: Between January 2002 and December 2015, patients who underwent right ventricular outflow tract reconstruction in 34 Japanese institutions using ePTFE-valved conduits with a diameter of ≥18 mm were included. All the valved conduits were made in the authors' institution and delivered to each participating institution. RESULTS: Overall, 502 patients were included. Early mortality was 1.4% and not related to conduit failure. The overall survival rate was 98.2% at 5 years and 96.6% at 10 years. Freedom from conduit explantation was 99.5% at 5 years and 89.0% at 10 years. Three patients (0.13 per 100 patient-years) developed infective endocarditis of the conduit, and only 1 patient required conduit removal. Pulmonary insufficiency was mild or less in 480 (96%) patients, and conduit stenosis was mild or less in 436 (88%) patients at the latest follow-up. CONCLUSIONS: By narrowing the analyses down to only ePTFE conduits with a large size, satisfactory long-term outcomes of these conduits with a fan-shaped valve and bulging sinuses were shown. These conduits would be among the optimal choices for right ventricular outflow tract reconstruction.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Fujita S, Yamagishi M, Miyazaki T, et al. Long-term results of large-calibre expanded polytetrafluoroethylene-valved conduits with bulging sinuses. Eur J Cardiothorac Surg. 2020. PMID: 32984875. doi:10.1093/ejcts/ezaa240

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。