膜部室间隔长度可预测经导管主动脉瓣置换术后传导障碍
该研究纳入195例使用CoreValve/Evolut R瓣膜行TAVR的患者,评估冠状面及瓣下膜部室间隔长度与植入深度的差值(ΔMSID)对术后传导障碍的预测价值。多因素回归显示两种ΔMSID均为唯一可调控预测因子,冠状面ΔMSID cutoff 3.2 mm,瓣下ΔMSID cutoff -0.2 mm,两者AUC相当,但冠状面测量可指导更多患者。
要点
- 术前应常规评估膜部室间隔长度以确定最佳植入深度。
- 冠状面ΔMSID≤3.2 mm与瓣下ΔMSID≤-0.2 mm预测传导障碍。
- 冠状面测量比瓣下测量可指导更多患者(95.9% vs 87.2%)。
核心结论
- 术前评估膜部室间隔长度应常规用于确定最佳植入深度,以降低自膨胀瓣膜TAVR术后传导障碍风险。
研究设计与样本
- 回顾性分析195例连续接受CoreValve/Evolut R瓣膜TAVR的患者,利用术前CT和术后造影评估冠状面及瓣下膜部室间隔长度、植入深度及ΔMSID。
主要发现
- 术后30天内6例(3.1%)需永久起搏器植入,31例(16.4%)发生左束支传导阻滞。
关键数值与推荐
- 冠状面ΔMSID≤3.2 mm预测传导障碍。
- 瓣下ΔMSID≤-0.2 mm预测传导障碍。
- 冠状面ΔMSID的AUC为0.717,瓣下ΔMSID的AUC为0.708。
临床怎么用
- TAVR术前应常规测量膜部室间隔长度,优先采用冠状面测量以指导植入深度,减少传导障碍。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Insufficient distance between membranous septum (MS) length and implant depth (ID) may aggravate mechanical compression of the conduction tissue by transcatheter aortic valve replacement (TAVR) prosthesis. We investigated the implication of MS length measured in the coronal view (coronal MS length) compared with infra-annular MS length from stretched vessel image to predict conduction disturbances following TAVR with CoreValve/Evolut R valves (Medtronic, Minneapolis, Minn). METHODS: Among 195 consecutive patients undergoing TAVR with CoreValve/Evolut R valves, we evaluated coronal, infra-annular MS lengths and ID, as well as MS length minus ID (ΔMSID) using pre-TAVR computed tomography and postprocedural angiography. RESULTS: Within 30 days, 6 (3.1%) required permanent pacemaker implantation and 31 (16.4%) developed left bundle branch block. When taking into account pre- and postprocedural parameters, multivariable logistic regression analysis revealed either coronal ΔMSID (odds ratio, 0.80; 95% confidence interval, 0.72-0.89; P < .001; cutoff point, 3.2 mm) or infra-annular ΔMSID (odds ratio, 0.84; 95% confidence interval, 0.76-0.92; P < .001; cutoff point, -0.2 mm) emerged as the only modifiable predictor of conduction disturbances. The area under the curve of coronal ΔMSID and infra-annular ΔMSID for predicting the occurrence of conduction disturbances were comparable (0.717 in coronal ΔMSID vs 0.708 in infra-annular ΔMSID; P = .761), but more patients could be guided by coronal MS length than infra-annular MS length (95.9% vs 87.2%; P = .002). CONCLUSIONS: Preprocedural assessment of MS length should be routinely adopted to determine the optimal ID to mitigate individual patient susceptibility to conduction disturbances after TAVR with self-expanding valves.
引用
- Chen YH, Chang HH, Liao TW, et al. Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement. J Thorac Cardiovasc Surg. 2020. PMID: 32891451. doi:10.1016/j.jtcvs.2020.07.072
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。