文献速递冠心病外科主动脉外科

人工血管吻合的大隐静脉桥长期通畅性评估

An evaluation of the long-term patency of the aortocoronary bypass graft anastomosed to a vascular prosthesis.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

该回顾性多中心研究纳入84例冠心病合并胸主动脉瘤同期手术患者,评估109条大隐静脉桥(吻合于人工血管75条、自体升主动脉34条)的长期通畅性。随访45.9±39.7个月,人工血管组通畅率显著低于自体升主动脉组(log rank P < 0.001),人工血管近端吻合是桥血管闭塞的唯一危险因素(P < 0.001)。

要点

  • 人工血管近端吻合的大隐静脉桥长期通畅率显著劣于自体升主动脉吻合
  • 人工血管近端吻合是桥血管闭塞的唯一独立危险因素
  • 同期手术时应尽可能避免以人工血管作为桥血管近端吻合部位

核心结论

  • 在冠心病与胸主动脉瘤同期手术中,如有可能应避免将大隐静脉桥近端吻合于人工血管,尽管仍需进一步研究验证。

研究设计与样本

  • 回顾性研究,纳入大阪心血管研究组3家机构84例冠心病合并胸主动脉瘤行同期CABG手术的患者,评估109条大隐静脉桥(人工血管组75条,自体升主动脉组34条),随访45.9±39.7个月,采用CTA或冠状动脉造影评估通畅性。

主要发现

  • 人工血管组通畅率显著低于自体升主动脉组:12个月100% vs 77.6%,36个月100% vs 52.7%,57个月100% vs 31.6%(log rank P < 0.001)。
  • 各靶血管均显示人工血管组通畅性较差:左前降支P = 0.050,右冠状动脉P = 0.045,左回旋支P = 0.051。
  • 无论靶血管狭窄程度如何均显示差异:重度狭窄P = 0.013,轻中度狭窄P = 0.029。
  • 单因素Cox比例风险模型显示,人工血管近端吻合部位是桥血管闭塞的唯一危险因素(P < 0.001)。

临床怎么用

  • 同期行CABG与胸主动脉瘤手术时,应优先选择自体升主动脉作为桥血管近端吻合部位,尽可能避免吻合于人工血管。

局限性

  • 为回顾性研究,样本量有限(84例患者、109条桥血管),仍需进一步研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Although concomitant surgery for coronary artery disease (CAD) and thoracic aortic aneurysm is performed often, the long-term patency of the coronary artery bypass grafting (CABG) anastomosed to a vascular prosthesis has not been fully investigated. Here, we explored the long-term patency of the graft in comparison with the proximal anastomosis site on the native ascending aorta or vascular prosthesis. METHODS: A total of 84 patients with concomitant CABG who underwent surgery for thoracic aortic aneurysm at 3 Osaka Cardiovascular Research Group institutes were retrospectively investigated for this study. The patency of 109 aortocoronary bypasses using saphenous vein grafts was evaluated with computed tomography angiography or coronary angiography, comparing the grafts anastomosed on the vascular prosthesis (group P, n = 75) to those anastomosed on the native ascending aorta (group N, n = 34). RESULTS: During 45.9 ± 39.7 months follow-up, significantly worse patency of the grafts in group P was revealed when compared with those in group N (100% vs 77.6% in 12 months, 100% vs 52.7% in 36 months and 100% vs 31.6% in 57 months, log rank P < 0.001). The poor patency of the grafts was confirmed in each target lesions (left anterior descending artery: P = 0.050, right coronary artery: P = 0.045, left circumflex artery: P = 0.051) and regardless of the severities of the target coronary vessels (severe stenosis: P = 0.013, mild-to-moderate stenosis: P = 0.029). Furthermore, an analysis of graft occlusion risk factors using the univariate Cox proportional hazards model revealed that the proximal anastomosis site on the vascular prosthesis was the sole risk factor for graft occlusion (P < 0.001). CONCLUSIONS: In the simultaneous surgery for CAD and thoracic aortic aneurysm, CABG design from vascular prosthesis to coronary artery should be avoided if possible, although further studies are warranted.