冠状动脉吻合模拟培训:定向干预优化成功率
本研究在2018至2019年单中心前瞻性观察胸外科住院医师冠状动脉吻合模拟课程。提供低仿真模拟器、高质量器械和导师指导后,独立练习率从21%升至82%,吻合评估评分从42/65提高到54/65,吻合时间平均缩短5分6秒。
要点
- 提供低仿真模拟器、器械和导师可提高住院医师独立练习率。
- 模拟培训可改善冠状动脉吻合评估评分并缩短吻合时间。
- 下一步需验证模拟课程对手术室实际操作的转化效果。
核心结论
- 提供低仿真冠状动脉吻合训练器、高质量器械和导师指导可提高住院医师独立练习率、胸外科主任协会评估评分并缩短吻合时间。
研究设计与样本
- 2018至2019年单中心前瞻性观察研究,胸外科培训项目所有住院医师参与,每人获低仿真吻合模拟器、高质量器械和导师,每季度正式评估。
主要发现
- 胸外科主任协会血管吻合评估中位评分从基线42/65升至第四季度54/65(P = .04)。
- 平均吻合时间缩短5分6秒(P = .02)。
- 12个月内初级住院医师吻合时间平均减少6分36秒,高级住院医师减少3分6秒(P = .02)。
临床怎么用
- 可为住院医师配备低仿真冠状动脉吻合模拟器、高质量器械和导师,鼓励独立及导师指导下练习。
- 定期采用胸外科主任协会血管吻合评估进行季度考核以追踪进展。
局限性
- 研究为单中心前瞻性观察,样本量有限,未报告手术室实际操作转化结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The role of simulation-based training in coronary artery bypass grafting remains undefined. Barriers to simulator use include clinical and personal obligations, insufficient materials, and lack of mentorship. The purpose of this study was to implement a longitudinal, residency-wide coronary anastomosis simulation curriculum. METHODS: A prospective observational study was conducted from 2018 to 2019 at a single academic center. All residents of the Thoracic Surgery training program participated. Each participant was provided a low-fidelity coronary anastomosis simulator, high-quality instruments, and faculty mentor. Formal assessments were held quarterly, and residents were encouraged to practice alone and with their mentor. Baseline and follow-up metrics were compared with simple descriptive statistics. RESULTS: Seventeen residents and 12 faculty participated in the study. Residents demonstrated increased use of the simulator, with 21% participating in independent practice at baseline and 82% in the fourth quarter (P = .02). The median score on the Thoracic Surgery Directors Association Vessel Anastomosis Assessment improved from 42 out of 65 at baseline to 54 out of 65 in the fourth quarter (P = .04), and mean anastomosis time was reduced by 5 minutes 6 seconds (P = .02). Over 12 months, junior residents demonstrated a mean reduction in anastomosis time of 6 minutes 36 seconds, and senior residents decreased anastomosis time by 3 minutes 6 seconds (P = .02). CONCLUSIONS: Providing residents with a low-fidelity coronary anastomosis trainer with high-quality instruments and a faculty mentor improved rates of independent practice, Thoracic Surgery Directors Association assessment scores, and anastomosis time. Our next step is validating the coronary simulator curriculum by measuring improvement of resident performance in the operating room.
引用
- Anand J, Doberne J, Wojnarski CM, et al. Coronary Anastomosis Simulation: Directed Interventions to Optimize Success. Ann Thorac Surg. 2020. PMID: 32891660. doi:10.1016/j.athoracsur.2020.06.099