心包液线粒体DNA水平与心脏术后房颤相关
该研究分析心脏手术后心包液和血液中的线粒体DNA、中性粒细胞及细胞因子/趋化因子,以探讨术后房颤(POAF)的炎症机制。100例冠状动脉旁路移植和/或心脏瓣膜手术患者结果显示,心包液mtDNA水平与POAF强烈相关(P < .001,AUC 0.74),而血液mtDNA无差异。
要点
- 心包液mtDNA水平与心脏术后房颤强烈相关(P < .001,AUC 0.74)。
- 心包液mtDNA及多种细胞因子水平术后高于血液。
- 心包液中性粒细胞浓度从基线0.8%升至48小时56%(P < .01)。
核心结论
- 心包腔术后炎症介质浓度高,其中心包液mtDNA与POAF发生强烈相关。
研究设计与样本
- 前瞻性观察研究,纳入100例冠状动脉旁路移植和/或心脏瓣膜手术患者,术中及术后4、12、24、48小时采集心包液和血液。
主要发现
- 术后心包液mtDNA及多种细胞因子水平高于血液。
- POAF患者心包液mtDNA水平显著高于非POAF患者(P < .001,AUC 0.74)。
- POAF组与非POAF组血液mtDNA浓度无差异(P = .897)。
- 心包液中性粒细胞浓度从基线0.8%升至48小时56%(P < .01)。
临床怎么用
- 心包液mtDNA可能作为POAF炎症机制的提示指标,并可能为新型治疗靶点提供线索。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, and is associated with increased morbidity and mortality. Inflammation has been implicated as an etiology of POAF. Mitochondrial DNA (mtDNA) has been shown to initiate inflammation. This study analyzed inflammatory mechanisms of POAF by evaluating mtDNA, neutrophils, and cytokines/chemokines in the pericardial fluid and blood after cardiac surgery. METHODS: Blood and pericardial fluid from patients who underwent coronary artery bypass or heart valve surgery, or both, were collected intraoperatively and at 4, 12, 24, and 48 hours postoperatively. Real-time polymerase chain reaction was used to quantify mtDNA in the pericardial fluid and blood. A Luminex (Luminex Corp, Austin, TX) assay was used to study cytokine and chemokine levels. Flow cytometry was used to analyze neutrophil infiltration and activation in the pericardial fluid. RESULTS: Samples from 100 patients were available for analysis. Postoperatively, mtDNA and multiple cytokine levels were higher in the pericardial fluid versus blood. Patients who had POAF had significantly higher levels of mtDNA in the pericardial fluid compared with patients who did not (P < .001, area under the curve 0.74). There was no difference in the mtDNA concentration in the blood between the POAF group and non-POAF group (P = .897). Neutrophil concentration increased in the pericardial fluid over time from a baseline of 0.8% to 56% at 48 hours (P < .01). CONCLUSIONS: The pericardial space has a high concentration of inflammatory mediators postoperatively. Mitochondrial DNA in the pericardial fluid was strongly associated with the development of POAF. This finding provides insight into a possible mechanism of inflammation that may contribute to POAF, and may offer novel therapeutic targets.
引用
- Manghelli JL, Kelly MO, Carter DI, et al. Pericardial Mitochondrial DNA Levels Are Associated With Atrial Fibrillation After Cardiac Surgery. Ann Thorac Surg. 2020. PMID: 32946846. doi:10.1016/j.athoracsur.2020.07.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。