无管剑突下胸腔镜胸腺切除术中头臂静脉损伤的处理
本文报告一例无管剑突下胸腔镜胸腺切除术中发生头臂静脉损伤的病例,术后3个月随访未发现额外并发症。作者指出,尽管该术式安全且微创,但术中并发症仍可能发生,外科医生应保持警惕。
要点
- 无管剑突下胸腔镜胸腺切除术中可能发生头臂静脉损伤。
- 头臂静脉因骨骼解剖特点成为胸腺切除术中最易损伤的血管。
- 术后3个月随访未发现额外并发症。
核心结论
- 无管剑突下胸腔镜胸腺切除术虽安全微创,但术中并发症仍可能发生,外科医生应谨慎。
研究设计与样本
- 病例报告,报告一例无管剑突下胸腔镜胸腺切除术中头臂静脉损伤。
主要发现
- 术中发生头臂静脉损伤。
- 术后3个月随访未发现额外并发症。
临床怎么用
- 行无管剑突下胸腔镜胸腺切除术时应警惕头臂静脉损伤的可能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
We have reported the usefulness of the subxiphoid video-assisted thoracoscopic surgery approach in thymectomy. However, such a new method may have unknown complications that rarely occur. The brachiocephalic vein has been considered to be the vessel that is most frequently injured when performing thymectomy because of the skeletal anatomy. We herein report a case of intraoperative injury of brachiocephalic vein using tubeless subxiphoid thoracoscopic thymectomy. No additional complications have been found in the 3 months since the operation. Though subxiphoid video-assisted thoracoscopic surgery thymectomy is a safe and less invasive operation, intraoperative complications are possible, and surgeons should express caution.
引用
- Jiang L, Chen H, Ang K, et al. Management of Brachiocephalic Vein Injury During Tubeless Subxiphoid Thoracoscopic Thymectomy. Ann Thorac Surg. 2020. PMID: 32738220. doi:10.1016/j.athoracsur.2020.05.153