双向腔肺分流术后Fontan手术失败的危险因素
该研究回顾1998至2018年525例功能性单心室患者行双向腔肺分流(BCPS)的结果,中位随访3.4年,407例完成Fontan手术,5例早期死亡。BCPS后1、2、3年免于Fontan失败分别为91.9%、87.3%、86.1%。左心发育不良综合征、不平衡型房室间隔缺损、较高肺动脉压力和心室功能减低是Fontan失败的危险因素。
要点
- BCPS二期姑息手术风险低,后续Fontan完成率高。
- 左心发育不良综合征、不平衡型房室间隔缺损是Fontan失败危险因素。
- BCPS时较高肺动脉压和心室功能减低增加Fontan失败风险。
核心结论
- BCPS二期姑息手术可低风险实施并提供良好的后续Fontan完成率。
- 左心发育不良综合征、不平衡型房室间隔缺损、较高肺动脉压力和心室功能减低是BCPS时Fontan失败的危险因素。
研究设计与样本
- 回顾性分析1998至2018年525例功能性单心室行BCPS患者的资料。
- 分析患者人口学、手术数据、超声心动图和心导管测量,评估BCPS后结局。
主要发现
- BCPS中位年龄4.7个月(四分位距3至7.4),左心发育不良综合征最常见。
- BCPS后中位随访3.4年(四分位距1.5至8.7),407例完成Fontan,50例等待,47例死亡,6例不适合Fontan,15例失访。
- 407例完成Fontan者中5例早期死亡。
- BCPS后1、2、3年免于Fontan失败分别为91.9%、87.3%、86.1%。
临床怎么用
- BCPS术前应评估肺动脉压力和心室功能,识别Fontan失败高危患者。
- 对左心发育不良综合征或不平衡型房室间隔缺损患者,BCPS后需密切监测Fontan完成情况。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Our aim was to evaluate the results of stage 2 palliation by means of bidirectional cavopulmonary shunt (BCPS) and to identify risk factors for failed Fontan completion. METHODS: Between 1998 and 2018, BCPS was performed on 525 patients with functional single ventricle. Patient demographics, surgical data, and echocardiographic and cardiac catheterization measurements were analyzed, and outcomes after BCPS were evaluated. RESULTS: The median age at BCPS was 4.7 months (interquartile range, 3 to 7.4). Hypoplastic left heart syndrome was the most frequent diagnosis. The median follow-up after BCPS was 3.4 years (interquartile range, 1.5 to 8.7); 407 patients underwent the Fontan procedure, 50 were waiting for Fontan completion, 47 died, 6 were considered not suitable for Fontan completion, and 15 were lost to follow-up. Of the 407 patients who underwent Fontan completion, there were 5 early deaths. Freedom from failed Fontan completion (mortality before, unsuitability for, and early mortality after the Fontan procedure) at 1, 2, and 3 years was 91.9%, 87.3%, and 86.1%, respectively. Risk factor analysis for failed Fontan completion revealed hypoplastic left heart syndrome (hazard ratio [HR] 4.1, P = .001), unbalanced atrioventricular septal defect (HR 10.1, P < .001), higher pulmonary artery pressure (HR 1.1, P = .040), and reduced ventricular function (HR 4.2, P = .001) as risks. CONCLUSIONS: Stage 2 palliation can be performed with minimal risk and provides excellent subsequent Fontan completion. Hypoplastic left heart syndrome, unbalanced atrioventricular septal defect, high pulmonary artery pressure, and reduced ventricular function at the time of BCPS were identified as risk factors for failure to successfully complete the Fontan procedure.
引用
- Ono M, Burri M, Mayr B, et al. Risk Factors for Failed Fontan Procedure After Stage 2 Palliation. Ann Thorac Surg. 2020. PMID: 32828751. doi:10.1016/j.athoracsur.2020.06.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。