文献速递主动脉外科

混合技术修复非A非B型主动脉夹层的早期结局

Early outcomes with a hybrid technique for repair of a non-A non-B aortic dissection.
PubMed 文献 · J Thorac Cardiovasc Surg · 2020-06-22

本研究回顾2013年1月至2018年12月共825例主动脉夹层患者,其中28例非A非B型夹层(累及主动脉弓、破口位于左颈总动脉与左锁骨下动脉之间)接受新型杂交手术。所有患者急诊手术,无院内死亡、无出血再探查、无截瘫、脑梗死、内漏或左锁骨下动脉闭塞,围术期无需血制品。早期随访39.12±15.04个月,1例失访、1例猝死,6个月CTA示远端主动脉弓和降主动脉直径较术前显著缩小。

要点

  • 杂交技术治疗非A非B型主动脉夹层无院内死亡,无内漏、截瘫等并发症。
  • 围术期无需血制品,6个月CTA示远端主动脉弓和降主动脉直径显著缩小。
  • 早期随访中假腔通畅持续存在但无症状,需进一步评估远期意义。

核心结论

  • 纳入主动脉弓的杂交技术是治疗非A非B型主动脉夹层安全、有效且简单的方法,可避免内漏、无需血制品,早期结局满意。

研究设计与样本

  • 回顾性单中心研究,2013年1月至2018年12月共825例主动脉夹层患者中,28例非A非B型夹层接受新型杂交手术。

主要发现

  • 所有患者急诊手术,无院内死亡、无出血再探查、无截瘫、脑梗死、内漏或左颈总动脉与左锁骨下动脉之间破口的左锁骨下动脉闭塞,围术期无需血制品。
  • 早期随访39.12±15.04个月(6.0-74.0个月),1例失访,1例猝死;CTA示主动脉弓和降主动脉假腔持续通畅但无症状。
  • 6个月CTA示远端主动脉弓直径31.94±6.95 mm、降主动脉直径34.84±4.15 mm,均显著小于术前(分别为36.76±4.15 mm和37.31±4.7 mm)。
  • 随访期间无截瘫、脑梗死、上肢缺血或左锁骨下动脉缺血事件。

临床怎么用

  • 对于破口位于左颈总动脉与左锁骨下动脉之间、累及主动脉弓但不累及升主动脉的非A非B型夹层,可考虑采用此杂交技术急诊手术。
  • 该技术无需血制品且避免内漏,但术后假腔可能持续通畅,需长期影像学随访。

局限性

  • 样本量小(28例),为单中心回顾性研究,随访时间有限,1例失访,结论需更大样本和更长随访验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study reports the early outcomes of patients with acute non-A non-B aortic dissection that involved the aortic arch but not the ascending aorta. METHODS: From January 2013 to December 2018, 825 patients presented with aortic dissection. Of these, 28 patients with non-A non-B dissection (classified as dissection extending into the aortic arch with entry between the left common carotid artery and the left subclavian arteries) underwent a novel hybrid surgery. Self modified stent-grafts (Micropart Corp, Shanghai, China) were implanted via median sternotomy. Clinical presentation, postoperative data, and early outcomes were recorded. RESULTS: All patients underwent an emergency operation. There were no in-hospital mortalities, reexplorations for hemorrhage, reports of paraplegia, cerebral infarctions, endoleaks, or left subclavian artery occlusions. No blood products were required during or after the operations. During the early follow-up at 39.12 ± 15.04 months (6.0-74.0 months), 1 patient was lost to follow-up, and 1 patient died suddenly. Computed tomography angiography showed false lumen patency persisted in the aortic arch and descending aorta without any symptoms. The 6-month computed tomography angiography showed significantly smaller distal aortic arch diameters (31.94 ± 6.95 mm) and descending aorta diameters (34.84 ± 4.15 mm) than measured preoperatively (36.76 ± 4.15 mm and 37.31 ± 4.7 mm, respectively). No paraplegia, cerebral infarction, upper limb ischemia, or left subclavian artery ischemia events were reported. CONCLUSIONS: Our inclusion aortic arch technique is a safe, effective, and simple treatment for non-A non-B aortic dissections that can avoid endoleaks, requires no blood products, and has satisfactory early outcomes.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Wang W, Piao H, Wang Y, et al. Early outcomes with a hybrid technique for repair of a non-A non-B aortic dissection. J Thorac Cardiovasc Surg. 2020. PMID: 32739160. doi:10.1016/j.jtcvs.2020.05.100

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。