文献速递瓣膜外科主动脉外科

二叶式主动脉瓣交界方向的简化测定方法

Simplified determination of commissural orientation in bicuspid aortic valves.
PubMed 文献 · Eur J Cardiothorac Surg · 2020-01-01

该研究分析62例二叶式主动脉瓣(BAV)患者的术前经食管超声心动图,比较4种交界方向(CO)测定方法。结果显示以非融合窦与融合窦中心连线法最简便,3种几何法结果几乎一致(组内相关系数0.98-0.99);而以对合中心测定会低估交界角度达30°,在非对称型BAV中差异显著(P=0.005)。

要点

  • 推荐用非融合窦与融合窦中心连线法测定BAV交界方向,简便且可重复。
  • 以对合中心测定会低估交界角度达30°,非对称型BAV尤易误导。
  • 术前超声明确交界方向有助于主动脉瓣修复的术中决策。

核心结论

  • BAV交界方向可用非融合窦与融合窦中心之间的线段可重复地测定;使用对合中心可能导致误导性结果,尤其见于非对称型BAV。

研究设计与样本

  • 回顾性分析62例BAV患者的术前经食管超声心动图,比较4种交界方向测定方法:对合中心法与3种基于几何中心(圆近似、椭圆近似、非融合窦与融合窦中心连线中点)的方法。

主要发现

  • 3种几何方法结果几乎一致,组内相关系数0.98-0.99,其中线段法最易使用。
  • 与几何中心相比,对合中心法低估交界角度达30°;差异显著,且在非对称型BAV(140-160°)中最明显(P=0.005)。

关键数值与推荐

  • 组内相关系数0.98-0.99(3种几何方法间)。
  • 对合中心法较几何中心低估交界角度达30°。
  • 非对称型BAV(140-160°)差异P=0.005。

临床怎么用

  • 术前经食管超声采用非融合窦与融合窦中心连线法测定交界方向,避免用对合中心,以辅助主动脉瓣修复的术中决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In bicuspid aortic valves (BAV), commissural orientation (CO) varies between 180° and close to 120°. Postoperative CO has a strong effect on repair durability, and different repair approaches have been proposed according to CO; it is thus important for aortic repair. A precise, simple and reproducible determination by preoperative echocardiography would facilitate intraoperative decision-making. We compared 4 different methods of determination of CO in BAV. METHODS: Preoperative transoesophageal echocardiograms of 62 patients with BAV were analysed. CO was measured using either the coaptation centre or the geometric centre of the root. The geometric centre of the root was determined through approximation using a circle or an ellipse, or the midpoint of a line between the centre of the non-fused and the fused sinuses. RESULTS: The 3 different geometric methods led to almost identical results (interclass coefficient 0.98-0.99), with the line segment being the easiest to use. The use of the coaptation centre was associated with the underestimation of commissural angle of up to 30° compared to the geometric centre; the discrepancy was significant and most pronounced for asymmetric BAV (140-160°; P = 0.005). CONCLUSIONS: CO can reproducibly be determined using a line segment between the centre of the non-fused and fused sinuses. The use of the coaptation centre can lead to misleading results, in particular in asymmetric BAVs.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Froede L, Schäfers S, Wagenpfeil G, et al. Simplified determination of commissural orientation in bicuspid aortic valves. Eur J Cardiothorac Surg. 2020. PMID: 32864689. doi:10.1093/ejcts/ezaa230

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。